EDWARDS LIFESCIENCES DR CUSTOM DEFINED PRODUCT; TRANSDUCER, PRESSURE, CATHETER TIP Back to Search Results
Model Number VO1335TS(PL)_
Device Problem Incorrect Or Inadequate Test Results (2456)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 08/24/2015
Event Type  malfunction  
Manufacturer Narrative
The lot number was not provided; therefore, a review of the manufacturing records could not be completed.Unfortunately, we did not receive the sample for examination in our product evaluation laboratory.Without return of the product, we are unable to perform a complete investigation into the root cause of the reported event.At this time, we cannot confirm the reported issue.
 
Event Description
It was reported that although the dpt zeroed before use, the arterial pressure shown on the colin monitor was abnormal during use.The actual value shown on the monitor is unknown but the values were low.The expected value, the shape of the waveform and if the value and waveform matched are unknown.It is also unknown if there were any error messages observed.It could not be confirmed if there were any occlusions, kinks or leaks.The sample of tracing was not available.The patient was not treated based on the inaccurate values and there were no patient complications reported.Device will not be returned due to the infection therefore it is not available for evaluation.
 
Manufacturer Narrative
Evaluation codes added.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CUSTOM DEFINED PRODUCT
Type of Device
TRANSDUCER, PRESSURE, CATHETER TIP
Manufacturer (Section D)
EDWARDS LIFESCIENCES DR
carretera sanchez, km 18 1/2
parque ind. de itabo
haina. san cristobal
DR 
Manufacturer (Section G)
EDWARDS LIFESCIENCES DR
carretera sanchez, km 18 1/2
parque ind. de itabo
haina. san cristobal
DR  
Manufacturer Contact
lynn selawski
1 edwards way
irvine, CA 92614
9497564386
MDR Report Key5117389
MDR Text Key27241957
Report Number2015691-2015-02592
Device Sequence Number1
Product Code DXO
Combination Product (y/n)N
Reporter Country CodeJA
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation Health Professional
Report Date 09/08/2015
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberVO1335TS(PL)_
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received Not provided
Initial Date FDA Received10/01/2015
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial