ADVANCED STERILIZATION PRODUCTS STERRAD® CYCLESURE® 24 BIOLOGICAL INDICATOR; INDICATOR, BIOLOGICAL (FRC) Back to Search Results
Catalog Number 14324
Device Problem Appropriate Term/Code Not Available (3191)
Patient Problem No Information (3190)
Event Date 11/13/2015
Event Type  malfunction  
Manufacturer Narrative
(b)(4).
 
Event Description
The customer reported a positive result with a cyclesure® 24 biological indicator (bi) after a completed sterrad® nx cycle.The chemical indicator (ci) changed color correctly.The subsequent bi result was negative.The affected load was reprocessed.There was no report of infection, injury or harm to patient(s) associated with this issue.Although there is no report of patient injury or harm and no prior incidents have resulted in serious injury, advanced sterilization products (asp) has determined in this situation sterility cannot be assured.Therefore, as a matter of policy asp had decided to report all incidents of positive cyclesure® 24 biological indicators.
 
Manufacturer Narrative
(b)(4).Asp investigation summary: the investigation included a review of the device history record (dhr), trending of the product malfunction code, trending of lot number, system risk analysis (sra), and product retains analysis.The dhr was reviewed and the involved lot met manufacturer specifications at the time of release.No anomalies were observed that would contribute to the customer's experienced issue.Trending analysis for the product code of 'suspected positive bi" was reviewed from august 2014 through february 2015 and revealed a significant trend which was addressed through capa.Trending analysis by lot number was reviewed from 08/15/2015 to 11/13/2015 and trending was not exceeded.The sra indicates the risk associated with exposure to biohazardous, pathogenic or infectious material is "low." the suspect positive cyclesure® bi was not returned for evaluation.Thirty-two retains bis were subject to functional evaluation.All thirty-two bis met specification.Also, no damage or leakage was observed with the retains after processing.It is unlikely the suspected positive bi was caused by a manufacturing issue as the retains met functional specification, dhr review found no anomalies that would contribute to a positive bi result, and lot history review found trending was not exceeded in this lot.An issue with sterrad® performance is also unlikely as the cycle passed and the customer stated subsequent bis were negative for growth.The cyclesure® retains met functional specification.As a result, there is not an issue with product performance when used per the instructions for use (ifu).The issue will continue to be tracked and trended.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
STERRAD® CYCLESURE® 24 BIOLOGICAL INDICATOR
Type of Device
INDICATOR, BIOLOGICAL (FRC)
Manufacturer (Section D)
ADVANCED STERILIZATION PRODUCTS
33 technology drive
irvine CA 92618
Manufacturer (Section G)
ADVANCED STERILIZATION PRODUCTS
33 technology drive
irvine CA 92618
Manufacturer Contact
joaquin kurz
irvine, CA 92618
MDR Report Key5291610
MDR Text Key33943277
Report Number2084725-2015-00562
Device Sequence Number1
Product Code FRC
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K994055
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 11/13/2015
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date01/31/2016
Device Catalogue Number14324
Device Lot Number22715264
Other Device ID Number14324
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Initial Date Manufacturer Received 11/13/2015
Initial Date FDA Received12/11/2015
Supplement Dates Manufacturer ReceivedNot provided
Supplement Dates FDA Received02/19/2016
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured08/01/2015
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-