• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ETHICON ENDO-SURGERY, LLC. ULTRACISION * SURG DEV, BLADES 5MM, ENDO; INSTRUMENT, ULTRASONIC SURGICAL

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ETHICON ENDO-SURGERY, LLC. ULTRACISION * SURG DEV, BLADES 5MM, ENDO; INSTRUMENT, ULTRASONIC SURGICAL Back to Search Results
Catalog Number HDH05
Device Problem Loss of Power (1475)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 11/25/2015
Event Type  malfunction  
Manufacturer Narrative
(b)(4).Additional information was received: after the operation, the blade tip was broken off and the broken tip will be returning with the device.The device was returned with the distal tip of the blade broken off and returned.The remaining blade portion was scratched, and with evidence of contact with metal in or out of the operative field.This blade tip portion may have broken off of the device during transport to our analysis site.The reported complaint was for: ¿activation issues." the device was functionally tested with a generator.During functional testing on gen04 an error code 5 was displayed.A probable cause of the device not activating and displaying an error code 5 is blade damage.Probable causes of blade damage, including breakage, are external contact during pre-op or general use, blade contact with other devices, staples or clips during the procedure or using any means other than the blade wrench to attach or detach the blade.Once minor blade damage has occurred, subsequent activations may increase damage severity and result in an error code 5 or blade lockout later in the procedure.The generator system will revert to standby mode, when the audible alarm (solid tone) and visual alarm indicator appear.The batch record was reviewed and no anomalies were noted during the manufacturing process.
 
Event Description
It was reported that during a laparoscopic cholecystectomy, the device suddenly became not to be activated soon at the third actuation.Another device was used to complete the case.There were no adverse consequences to the patient.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Type of Device
INSTRUMENT, ULTRASONIC SURGICAL
Manufacturer (Section D)
ETHICON ENDO-SURGERY, LLC.
475 calle c
guaynabo PR 00969
Manufacturer (Section G)
ETHICON ENDO-SURGERY, LLC
475 calle c
guaynabo PR 00969
Manufacturer Contact
milton garrett
4545 creek road ml 120a
cincinnati, OH 45242
5133378865
MDR Report Key5347566
MDR Text Key35558601
Report Number3005075853-2016-00102
Device Sequence Number1
Product Code LFL
Combination Product (y/n)N
Reporter Country CodeJA
PMA/PMN Number
K990362
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation Other
Type of Report Initial
Report Date 11/26/2015
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date10/11/2019
Device Catalogue NumberHDH05
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer12/10/2015
Is the Reporter a Health Professional? No
Initial Date Manufacturer Received 12/17/2015
Initial Date FDA Received01/06/2016
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured11/11/2014
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-