MAUDE Adverse Event Report: ST. JUDE MEDICAL, COSTA RICA LTDA PRESSURE WIRE AERIS G8; TRANSDUCER, PRESSURE,CATHETER TIP

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ST. JUDE MEDICAL, COSTA RICA LTDA PRESSURE WIRE AERIS G8; TRANSDUCER, PRESSURE,CATHETER TIP Back to Search Results
Model Number C12058
Device Problem Difficult to Advance (2920)
Patient Problem No Code Available (3191)
Event Date 03/05/2016
Event Type  Injury  
Manufacturer Narrative
(b)(4).
 
Event Description
Using a pressurewire aeris, ffr was performed on a restenosed stented bifurcation lesion of the lad/om1.There was difficulty advancing the catheter through the stent struts, but the catheter was delivered and ffr was performed with a value of.92 not requiring intervention.When the pressurewire was removed, it was noticed the tip of the pressurewire was still in the distal lad.A snare was used to remove the distal tip without incident.
 
Manufacturer Narrative
(b)(4).The results of the investigation concluded that the corewire was fractured into two sections at the distal tip, and the tip coil was fractured and separated from the weld joint.The combined length of the two corewire sections indicated there was no missing material from the distal tip assembly.The device met specifications prior to leaving sjm manufacturing facilities as supported by a review of the device history record.There was no evidence found to suggest the incident was due to an intrinsic defect in the returned device.Although the exact cause of the reported positioning issue remains unknown, the corewire and tip coil damage is consistent with the reported positioning issue.The cause of the corewire and tip coil damage is consistent with forcible contact during use.The pressurewire instructions for use (ifu) states that excessive manipulation of the pressurewire when the sensor element or pressurewire tip is located in sharp bend may cause damage or tip fracture.The pressurewire instructions for use (ifu) states that torquing the pressurewire against resistance or repeated attempts to cross a total vessel occlusion may cause damage and/or fracture, which may lead to a portion of pressurewire separating from the tip.The pressurewire instructions for use (ifu) states that the user should advance or withdraw the pressurewire slowly and never push, withdraw or torque the pressurewire if it meets resistance.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PRESSURE WIRE AERIS G8
Type of Device
TRANSDUCER, PRESSURE,CATHETER TIP
Manufacturer (Section D)
ST. JUDE MEDICAL, COSTA RICA LTDA
parque industrial, zona franca coyol s.a.
edificio #44b, calle 0, avenida 2, coyol
alajuela, costa rica 1897- 4050
CS  1897-4050
Manufacturer (Section G)
ST. JUDE MEDICAL, COSTA RICA LTDA
parque industrial, zona franca coyol s.a.
edificio #44b, calle 0, avenida 2, coyol
alajuela, costa rica 1897- 4050
CS   1897-4050
Manufacturer Contact
denise johnson
5050 nathan lane north
plymouth, MN 55442
6517565400
MDR Report Key5536477
MDR Text Key41512962
Report Number3008452825-2016-00041
Device Sequence Number1
Product Code DXO
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K131452
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Reporter Occupation Health Professional
Type of Report Initial,Followup
Report Date 03/07/2016
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Expiration Date09/30/2017
Device Model NumberC12058
Device Catalogue NumberC12058
Device Lot Number5282657
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer04/06/2016
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 03/07/2016
Initial Date FDA Received03/30/2016
Supplement Dates Manufacturer ReceivedNot provided
Supplement Dates FDA Received04/15/2016
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured10/30/2015
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
Patient Age53 YR
Patient Weight90
-
-