Device Problems Moisture Damage (1405); Loss of Power (1475)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Type  malfunction  
Manufacturer Narrative
The pump has not been returned to animas for evaluation.If the device is returned, an evaluation shall be completed and a supplemental report will be filed.No conclusions can be made at this time.
 
Event Description
On (b)(6) 2016, the reporter contacted animas, alleging a power (moisture ingress) issue.Reportedly, the pump had lost power.It was noted that there was moisture in the battery compartment.There was no allegation of an adverse event associated with this complaint.This complaint is being reported because the user may be unaware that the pump has lost power, leading to under delivery.
 
Manufacturer Narrative
Follow-up #1 date of submission 08/25/2016 device evaluation: the pump has been returned and evaluated by product analysis on 08/02/2016 with the following findings: a review of the black box data showed an unexplained reboot and call service alarms on the reported event date.A visual inspection of the pump showed visible rust and corrosion in the battery compartment.The pump failed a leak test due to a crack in the battery compartment.The pump was exercised for 24 hours with no issues.The pump cover was opened and internal moisture ingress was found.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ANIMAS VIBE
Type of Device
INSULIN INFUSION PUMP
Manufacturer (Section D)
ANIMAS CORPORATION
200 lawrence dr
west chester PA 19380 3428
Manufacturer (Section G)
ANIMAS CORPORATION
200 lawrence dr
west chester PA 19380 3428
Manufacturer Contact
karin sargrad
200 lawrence dr
west chester, PA 19380-3428
4843561808
MDR Report Key5791412
MDR Text Key50179714
Report Number2531779-2016-16004
Device Sequence Number1
Product Code MDS
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P130007
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type consumer
Reporter Occupation Patient
Type of Report Initial,Followup
Report Date 06/24/2016
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Lay User/Patient
Other Device ID Number011084040610008221047038216
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer07/14/2016
Is the Reporter a Health Professional? No
Was the Report Sent to FDA? Yes
Device Age14 MO
Initial Date Manufacturer Received 06/24/2016
Initial Date FDA Received07/13/2016
Supplement Dates Manufacturer ReceivedNot provided
Supplement Dates FDA Received08/25/2016
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured04/15/2015
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Unknown
Patient Sequence Number1
Patient Age34 YR
-
-