• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ANIMAS CORPORATION ANIMAS VIBE; INSULIN INFUSION PUMP

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ANIMAS CORPORATION ANIMAS VIBE; INSULIN INFUSION PUMP Back to Search Results
Device Problems Premature Discharge of Battery (1057); Crack (1135); Battery Problem (2885); Moisture or Humidity Problem (2986)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Type  malfunction  
Manufacturer Narrative
The pump has not been returned to animas for evaluation.If the device is returned, an evaluation shall be completed and a supplemental report will be filed.No conclusions can be made at this time.
 
Event Description
On (b)(6) 2016, the reporter contacted animas, alleging that battery life of the pump was less than expected.The reporter claimed that the battery compartment was cracked and there was moisture in the battery compartment.This complaint is being reported because the issue may result in a long term cessation of insulin delivery if the user is unable to resolve the alarm.There was no indication that the product caused or contributed to an adverse event.
 
Manufacturer Narrative
Follow-up #1: date of submission 10/04/2016.Device evaluation: the device has been returned and evaluated by product analysis on 09/09/2016 with the following findings: a review of the pump¿s black box revealed evidence of a short battery life in a form of a sudden voltage drop leading to a cs 128 alarm.The battery compartment was found to be cracked at the threads on the side.The returned battery cap was able to fit securely.There was moisture corrosion observed in the battery canister.A leak test failed due to battery compartment leak.The pump powered up correctly and the ez-prime steps were performed correctly.All currents draw were within specification.The ¿short battery life¿ complaint was unable to be duplicated.The pump¿s cover was removed and there was no moisture ingress or any intermittent condition found to the printed circuit board.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ANIMAS VIBE
Type of Device
INSULIN INFUSION PUMP
Manufacturer (Section D)
ANIMAS CORPORATION
200 lawrence dr
west chester PA 19380 3428
Manufacturer (Section G)
ANIMAS CORPORATION
200 lawrence dr
west chester PA 19380 3428
Manufacturer Contact
karin sargrad
200 lawrence dr
west chester, PA 19380-3428
4843561808
MDR Report Key5845759
MDR Text Key52491141
Report Number2531779-2016-18846
Device Sequence Number1
Product Code MDS
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P130007
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type consumer
Reporter Occupation Patient
Type of Report Initial,Followup
Report Date 07/17/2016
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Lay User/Patient
Other Device ID Number011084040610010521809847216
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer08/13/2016
Is the Reporter a Health Professional? No
Was the Report Sent to FDA? Yes
Device Age5 MO
Initial Date Manufacturer Received 07/17/2016
Initial Date FDA Received08/03/2016
Supplement Dates Manufacturer ReceivedNot provided
Supplement Dates FDA Received10/04/2016
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured01/25/2016
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Unknown
Patient Sequence Number1
Patient Age51 YR
-
-