IRIS INTERNATIONAL ICHEM VELOCITY AUTOMATED URINE CHEMISTRY SYSTEM; AUTOMATED URINALYSIS SYSTEM Back to Search Results
Catalog Number 700-7177-001
Device Problems Leak/Splash (1354); Device Operates Differently Than Expected (2913)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 08/24/2016
Event Type  malfunction  
Manufacturer Narrative
The field service engineer (fse) was at the customer site and inspected the connectors for the color gravity module (cgm) tubing.The tubing on the right side of the cgm was loose.The fse tightened the connectors and there were no more leaks.The fse also switched the settings to primary (iris fully automated), entered the correct lot numbers for the strips and the controls, and re-ran qc with no issues.The repairs were verified per established service procedures.(b)(4).
 
Event Description
The customer reported that there was a contained fluid leak that consisted of a few drops of possible wash solution and urine on their ichem velocity automated urine chemistry system.The customer also reported that they are unable to get qc to run.Erroneous patient results were not generated and there was no change or effect to patient treatment in connection to the event.The customer was wearing personal protective equipment (ppe), there was no direct exposure of mucous membranes.There was no injury or medical attention required.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ICHEM VELOCITY AUTOMATED URINE CHEMISTRY SYSTEM
Type of Device
AUTOMATED URINALYSIS SYSTEM
Manufacturer (Section D)
IRIS INTERNATIONAL
9172 eton ave
chatsworth CA 91311
Manufacturer (Section G)
IRIS INTERNATIONAL
9172 eton ave
chatsworth CA 91311
Manufacturer Contact
gopal mohanty
9172 eton avenue
chatsworth, ca, CA 91311
8185277379
MDR Report Key5946211
MDR Text Key54561694
Report Number2023446-2016-00362
Device Sequence Number1
Product Code KQO
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K101852
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type health professional,user faci
Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date 08/24/2016
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number700-7177-001
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 08/24/2016
Initial Date FDA Received09/13/2016
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured03/08/2016
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Unknown
Patient Sequence Number1
-
-