SMITH & NEPHEW, INC. FLEXIBLE PASSING PIN, 13.50 X 2.4MM; ACCESSORIES, ARTHROSCOPIC Back to Search Results
Catalog Number 72201594
Device Problems Break (1069); Detachment Of Device Component (1104); Failure to Advance (2524)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 10/11/2013
Event Type  malfunction  
Manufacturer Narrative
Visual inspection and functional testing could not be performed because the device in question was not returned for evaluation.Thus, the complaint could not be verified, nor could the root cause be determined with confidence.There are no indications that would suggest the device did not meet product specifications upon release into distribution.
 
Event Description
The tip broke off in the patient during an acl replacement utilizing the flexible passing pin, 13.50 x 2.4mm.The surgeon was having a hard time getting pin to pass through bone.It would not pass through and with multiple attempts to pass it finally broke.The broken piece was retrieved with grasper.A back-up device was available for use.No patient injury or other complications were reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FLEXIBLE PASSING PIN, 13.50 X 2.4MM
Type of Device
ACCESSORIES, ARTHROSCOPIC
Manufacturer (Section D)
SMITH & NEPHEW, INC.
130 forbes boulevard
mansfield MA 02048
Manufacturer (Section G)
SMITH & NEPHEW, INC.
130 forbes boulevard
mansfield MA 02048
Manufacturer Contact
jim gonzales
150 minuteman road
andover, MA 
5123585706
MDR Report Key5963080
MDR Text Key55163344
Report Number1219602-2016-00710
Device Sequence Number1
Product Code NBH
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
EXEMPT
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Reporter Occupation Health Professional
Type of Report Initial
Report Date 10/11/2013
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date03/31/2018
Device Catalogue Number72201594
Device Lot Number50453366
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 10/11/2013
Initial Date FDA Received09/20/2016
Date Device Manufactured04/17/2013
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage N
Patient Sequence Number1
-
-