Model Number N/A
Device Problem Insufficient Information (3190)
Patient Problem No Information (3190)
Event Type  Injury  
Manufacturer Narrative
The product identification necessary to review manufacturing history was not provided.Current information is insufficient to permit a conclusion as to the cause of the event.Event is being reported to fda on one medwatch since the limited information available indicates that a revision procedure may be necessary.Should additional information be received regarding a revision procedure, the complaint will be reassessed and, if warranted, further medwatch reports will be submitted.
 
Event Description
A distal bicep reattachment revision has been indicated due to unknown postoperative failure of the fixation system.No revision has been reported to date.
 
Manufacturer Narrative
This follow-up report is being submitted to relay additional information.Reported event was unable to be confirmed as lot number of device involved in the incident is unknown.Device history record (dhr) review was unable to be performed as the lot number of the device involved in the event is unknown.Review of the complaint history determined that no further action is required.It was relayed that an older version of the surgical technique was used; therefore, an expressbraid was not used in the surgery.This likely led to the failure of the device.Root cause determined to be incorrect surgical technique.A summary of the investigation was sent to the complainant conveying proper surgical technique and use of the device.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
2.9MM TOGGLELOC WITH ZIPLOOP WITH NEEDLES, #2 MAXBRAID
Type of Device
STAPLE, FIXATION
Manufacturer (Section D)
BIOMET SPORTS MEDICINE
56 e. bell drive
warsaw IN 46582
Manufacturer (Section G)
BIOMET ORTHOPEDICS
56 e. bell drive
warsaw IN 46582
Manufacturer Contact
megan haas
56 e. bell drive
warsaw, IN 46582
5743726700
MDR Report Key6024648
MDR Text Key57246424
Report Number0001825034-2016-04096
Device Sequence Number1
Product Code JDR
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
PK141263
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 05/08/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Physician
Device Model NumberN/A
Device Catalogue Number110017308
Other Device ID NumberN/A
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 09/14/2016
Initial Date FDA Received10/12/2016
Supplement Dates Manufacturer ReceivedNot provided
Supplement Dates FDA Received05/08/2017
Was Device Evaluated by Manufacturer? Yes
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Removal/Correction NumberN/A
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
-
-