• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: DEPUY ORTHOPAEDICS, INC. PFC STEM TRIAL EXTRACT; KNEE INSTRUMENT/TRIAL

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

DEPUY ORTHOPAEDICS, INC. PFC STEM TRIAL EXTRACT; KNEE INSTRUMENT/TRIAL Back to Search Results
Catalog Number 865226
Device Problem Break (1069)
Patient Problem No Information (3190)
Event Date 09/27/2016
Event Type  malfunction  
Manufacturer Narrative
This complaint is still under investigation.Depuy will notify the fda of the results of this investigation once it has been completed.(b)(4).If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event Description
Extractor shaft has come away from handle.Threaded tip has snapped off.
 
Manufacturer Narrative
This complaint is still under investigation.Depuy will notify the fda of the results of this investigation once it has been completed.
 
Manufacturer Narrative
Conclusion and justification status for mdr: examination of the submitted 865226 pfc stem trial extract confirmed the threaded tip has broken off and was not returned.The investigation also confirms the breakage of the shaft from the handle.The observed breakage is consistent with ductile overload.The root cause of the ductile overload is attributed to suspected levering of the instrument side to side while attempting to remove the fluted rod from the patient bone canal.No evidence was found indicating product error was a contributing factor and the need for corrective action was not indicated.Continue to monitor via sep-419.Depuy considers the investigation closed at this time.Should additional information be received, the information will be reviewed and the investigation will be re-opened as necessary.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PFC STEM TRIAL EXTRACT
Type of Device
KNEE INSTRUMENT/TRIAL
Manufacturer (Section D)
DEPUY ORTHOPAEDICS, INC.
700 orthopaedic drive
warsaw IN 46582
Manufacturer (Section G)
DEPUY ORTHOPAEDICS, INC.
700 orthopaedic drive
warsaw IN 46582
Manufacturer Contact
chad gibson
700 orthopaedic drive
warsaw, IN 46581
5743725905
MDR Report Key6043390
MDR Text Key57982376
Report Number1818910-2016-29840
Device Sequence Number1
Product Code HWB
Combination Product (y/n)N
Reporter Country CodeUS
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional
Reporter Occupation Health Professional
Type of Report Initial,Followup,Followup
Report Date 10/11/2016
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number865226
Device Lot NumberG0508G
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer11/01/2016
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 10/11/2016
Initial Date FDA Received10/20/2016
Supplement Dates Manufacturer ReceivedNot provided
Not provided
Supplement Dates FDA Received11/07/2016
11/21/2016
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured05/15/2008
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Unknown
Patient Sequence Number1
-
-