Device Problem Material Fragmentation (1261)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 11/25/2016
Event Type  malfunction  
Manufacturer Narrative
This report is for one (1) unknown metallic fragment.It is unknown if the fragments were generated from the screws or the plate.Possible additional device product code: hwc.It is unknown if the fragments were generated from the explanted screws or from the implanted the plate.As such implant/explant date is not applicable.Device is not expected to be returned for manufacturer review/investigation.(b)(6).Without a lot number the device history records review could not be completed.The investigation could not be completed; no conclusion could be drawn, as no product was received.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event Description
Device report from synthes europe reports an event in (b)(6) as follows: it was reported that the reported devices were used in hallux valgus correction surgery on (b)(6) 2016.The surgeon implanted a va (variable angle) locking plate and three locking screws.He did a final check after he concluded with a driver.It was needed to change the rotation; therefore he extracted two of the screws and changed them.As he removed the screws, surgeon stated that torque was too strong and, moreover the extraction was very hard even though it was just right after he inserted the screw.Further while removing the screw a metallic fragments like lint came out from the variable angle hole.Surgery was prolonged for 2 minutes due to reported issues.There is no information available about patient and surgical outcome.Concomitant devices reported as: 2.4/2.7mm ti va lckng x-plate extra small-sterile (part # 04.211.201s, lot # 9414726, quantity 1), 2.7mm ti va lckng scr slf-tpng with t8 stardrive recess 22mm (part # 04.211.022s, lot # 9613647, quantity 2), 2.7mm ti va lckng scr slf-tpng with t8 stardrive recess 16mm (part # 04.211.016s, lot # lo33257, quantity 1), 2.7mm ti va lckng scr slf-tpng with t8 stardrive recess 20mm (part # 04.211.020s, lot # lo97230, quantity 1).This report is for one (1) unknown metallic fragment.It is unknown if the fragments were generated from the screws or the plate.This is report 1 of 1 for (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Type of Device
PLATE, FIXATION, BONE
Manufacturer (Section D)
SYNTHES USA
1302 wrights lane east
west chester PA 19380
Manufacturer Contact
michael cote
1302 wrights lane east
west chester, PA 19380
6107195000
MDR Report Key6180986
MDR Text Key62679673
Report Number2520274-2016-15691
Device Sequence Number1
Product Code HRS
Combination Product (y/n)N
Reporter Country CodeJA
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation Physician
Type of Report Initial
Report Date 11/25/2016
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 11/25/2016
Initial Date FDA Received12/16/2016
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Type of Device Usage Unknown
Patient Sequence Number1
Treatment
ONE (1) 2.4/2.7MM TI VA LCKNG X-PLATE(04.211.201S); ONE (1) 2.7MM TI VA LCKNG SCR 16MM (04.211.016S); ONE (1) 2.7MM TI VA LCKNG SCR 20MM (04.211.020S); TWO (2) 2.7MM TI VA LCKNG SCR 22MM (04.211.022S)
-
-