STRYKER LEIBINGER FREIBURG BONE SCREWS, CROSS-PIN, DIAM.2.0X12MM, (5/PACKAGE); IMPLANT Back to Search Results
Catalog Number 50-20412
Device Problems Break (1069); Detachment Of Device Component (1104)
Patient Problem Foreign Body In Patient (2687)
Event Date 01/06/2017
Event Type  malfunction  
Manufacturer Narrative
The device has not yet been received at the manufacturer for testing.An evaluation will be conducted upon receipt of the device, and a follow-up report will be submitted after the quality investigation is complete.
 
Event Description
It was reported that a screw (part# 50-20412) head broke off while using the trocar.The screw end is still in the patient.Part# 62-00414 x 1 the spring popped out of cheek retractor.However, the case was finished with no surgical delay.
 
Manufacturer Narrative
The reported event could be confirmed.In the related ti 4690/17 it was stated: one bone screw, cross-pin, 2.0xxxmm broken during surgery, was returned in order to determine the root cause of the failure.The returned screw was examined regarding its dimensions, chemical composition (edx analysis) as well as by light and scanning electron microscopy.The (measurable) dimensions are in accordance with the specification.The chemical composition conforms to the specification - (b)(4).The investigation shows that the screw broke as a result of too high torsional forces in forced rupture mode during the insertion.The fracture surface shows the typical flow structures of a ductile torsional breakage.The root cause of the failure could have been a too small diameter or a too low deepness of the pilot hole.Indications for material or manufacturing related problems were not found in this investigation.No corrective and/or preventive actions are deemed necessary at this time.The complaint is added to the complaint trend.
 
Event Description
It was reported that a screw (part# 50-20412) head broke off while using the trocar.The screw end is still in the patient.Part# 62-00414 x 1 the spring popped out of cheek retractor.However, the case was finished with no surgical delay.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BONE SCREWS, CROSS-PIN, DIAM.2.0X12MM, (5/PACKAGE)
Type of Device
IMPLANT
Manufacturer (Section D)
STRYKER LEIBINGER FREIBURG
boetzingerstr. 41
freiburg D-791 11
Manufacturer (Section G)
STRYKER LEIBINGER FREIBURG
boetzingerstr. 41
freiburg D-791 11
Manufacturer Contact
jonathan schell
boetzingerstr. 41
freiburg D-791-11
76145120
MDR Report Key6285839
MDR Text Key66335375
Report Number0008010177-2017-00022
Device Sequence Number1
Product Code JEY
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K022185
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 07/18/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator No Information
Device Catalogue Number50-20412
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer03/22/2017
Is the Reporter a Health Professional? No
Initial Date Manufacturer Received 01/06/2017
Initial Date FDA Received01/30/2017
Supplement Dates Manufacturer Received01/06/2017
Supplement Dates FDA Received07/18/2017
Was Device Evaluated by Manufacturer? No
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-