BOSTON SCIENTIFIC - MARLBOROUGH ENDOVIVE¿ SAFETY PEG KIT; TUBES, GASTROINTESTINAL (AND ACCESSORIES) Back to Search Results
Model Number M00566470
Device Problem Difficult to Advance (2920)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 01/12/2017
Event Type  malfunction  
Manufacturer Narrative
(b)(4).The device has not been received for analysis.Upon receipt and completion of the failure analysis of the complaint device, if there is any further relevant information from that review, a supplemental medwatch will be filed.
 
Event Description
It was reported to boston scientific corporation that an endovive safety peg kit push method was used during a percutaneous endoscopic gastrostomy (peg) placement procedure performed on (b)(6) 2017.According to the complainant, during the procedure, as the peg tube was pulled through patient's stomach, it got stuck at the transition zone between the hard and soft plastic.When the device was pulled out, it was noted that the flexible peg tube had either rolled back away from the stiff end or the connection between the flexible tubing and the stiff end was imperfect.The procedure was completed with a new endovive safety peg kit push method.There were no patient complications reported as a result of this event.The patient's condition at the conclusion of the procedure was reported to be fine.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ENDOVIVE¿ SAFETY PEG KIT
Type of Device
TUBES, GASTROINTESTINAL (AND ACCESSORIES)
Manufacturer (Section D)
BOSTON SCIENTIFIC - MARLBOROUGH
100 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
BOSTON SCIENTIFIC - MARLBOROUGH
100 boston scientific way
marlborough MA 01752
Manufacturer Contact
nancy cutino
100 boston scientific way
marlborough, MA 01752
5086834000
MDR Report Key6297843
MDR Text Key66439402
Report Number3005099803-2017-00164
Device Sequence Number1
Product Code KNT
UDI-Device Identifier08714729748397
UDI-Public(01)08714729748397(17)20180430(10)19636595
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K031538
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Reporter Occupation Physician
Type of Report Initial
Report Date 01/12/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date04/30/2018
Device Model NumberM00566470
Device Catalogue Number6647
Device Lot Number19636595
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 01/12/2017
Initial Date FDA Received02/02/2017
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured08/25/2016
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-