BOSTON SCIENTIFIC - COSTA RICA (HEREDIA) ROTAWIRE¿ AND WIRECLIP¿ TORQUER; CATHETER, CORONARY, ATHERECTOMY Back to Search Results
Model Number H802228240022
Device Problem Physical Resistance (2578)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 02/20/2017
Event Type  malfunction  
Manufacturer Narrative
(b)(4).Device evaluated by manufacturer: the device was returned for analysis.The device has excessive rotational marks and it has evidence of rotational wear in the body of the wire.It is broken at 200 cm from the proximal section.The section broken and the spring tip were returned.Overall length could not be measured due to device condition (wire broken).Overall dimension (od) of distal tip was within specification.The manufacturing batch record review confirmed that the device met all material, assembly and performance specifications.The most probable root cause is considered handling damage as the event occurred without direct patient contact.(b)(4).
 
Event Description
Reportable based on device analysis completed on 31 march 2017.Same case as mdr id:2134265-2017-03764.It was reported that resistance was encountered and the burr did not rotate.A 330 cm rotawire¿ and a rotalink¿ plus were selected for use.During preparation, the burr had met resistance against the wire and it did not rotate due to friction.The procedure was completed with another of the same device.No patient complications were reported.However, device analysis revealed that the rotawire was fractured.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ROTAWIRE¿ AND WIRECLIP¿ TORQUER
Type of Device
CATHETER, CORONARY, ATHERECTOMY
Manufacturer (Section D)
BOSTON SCIENTIFIC - COSTA RICA (HEREDIA)
302 parkway
la aurora
heredia
CS 
Manufacturer (Section G)
BOSTON SCIENTIFIC - COSTA RICA (HEREDIA)
302 parkway
la aurora
heredia
CS  
Manufacturer Contact
sonali arangil
one scimed place
maple grove, MN 55311
7634941700
MDR Report Key6515798
MDR Text Key73499313
Report Number2134265-2017-03706
Device Sequence Number1
Product Code MCX
UDI-Device Identifier08714729195566
UDI-Public(01)08714729195566(17)20181130(10)0020005223
Combination Product (y/n)N
PMA/PMN Number
P900056
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,distri
Reporter Occupation Physician
Type of Report Initial
Report Date 03/31/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date11/30/2018
Device Model NumberH802228240022
Device Catalogue Number22824-002
Device Lot Number0020005223
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/24/2017
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 03/31/2017
Initial Date FDA Received04/24/2017
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured11/30/2016
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-