MAUDE Adverse Event Report: ARJOHUNTLEIGH POLSKA SP. Z O.O. MALIBU; BATH, HYDRO-MASSAGE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ARJOHUNTLEIGH POLSKA SP. Z O.O. MALIBU; BATH, HYDRO-MASSAGE Back to Search Results
Model Number AZR33116-GB
Device Problem Microbial Contamination of Device (2303)
Patient Problem No Patient Involvement (2645)
Event Type  malfunction  
Manufacturer Narrative
(b)(4).Additional information will be provided upon conclusion of the manufacturer's investigation.
 
Event Description
Arjohuntleigh has received information about 5 malibu bath systems affected by bacteria pseudomonas aeruginosa.These allegations were limited to one customer: colten care, uk and it has been suggested that arjohuntleigh baths could have been the root cause of the contamination.Currently arjohuntleigh is in the process of gathering proofs whether the allegation originated by this particular customer could be confirmed.
 
Manufacturer Narrative
(b)(4).(b)(4) is still in the process of gathering more information regarding the issue.The investigation has been planned by different sites of the company to clarify the customer's allegation.Additional information will be provided no later then (b)(6) 2017.
 
Manufacturer Narrative
Arjohuntleigh have acknowledged that pseudomonas aeruginosa is extremely common bacteria that is present in moist environments such as soil, water, sinks and showers and often found in spas or purified water system operators.Pseudomonas grows in water and thrives at warm temperatures.It grows quickest if the water is allowed to sit without movement.At this time we are not able to confirm the source of the bacteria reported.This is the subject of the investigation that is still ongoing.A follow-up report will be provided as soon as the conclusion of the investigation would become available.
 
Manufacturer Narrative
The investigation including analysis of potential sources of contamination allowed to exclude the manufacturing process as the source of bacteria.The results of microbiological test performed on swabs taken from cold, hot inlets, tap and filter were negative (presumptive pseudomonas unconfirmed).The test of the water supply use during manufacture's quality control process did not reveal any presence of bacteria.Further investigation is ongoing.A follow-up report will be provided as soon as the conclusion of the investigation would become available.
 
Manufacturer Narrative
Arjohuntleigh received information about 5 complaints raised by one particular customer facility (b)(6).Following the information provided by (b)(6) (which was providing a water test results for (b)(6)), a pseudomonas aeruginosa bacteria was found in five arjohuntleigh malibu baths in two (b)(6) facilities: (b)(6) (nursing home in (b)(6)) and (b)(6) (nursing home in (b)(6)).The baths in question were installed 2 weeks before test for bacteria presence was conducted.This report concerns malibu bath with model number azr33116-gb and serial number (b)(4), located in (b)(6).The customer facility representative did not disclose whether the system has already been used, or not.As a precautionary measure, the customer decided to take the baths out of use until the bath was decontaminated by 3rd party water treatment consultancy services (b)(6).No injury was reported as a result of alleged contamination.When reviewing similar reportable events with the involvement of the malibu baths, it was possible to determine a low number of cases where it was indicated that the internal plumbing of the bath was contaminated.The occurrence rate observed for this failure mode is currently considered to be very low.The investigation including analysis of potential sources of contamination allowed to exclude the manufacturing process as the source of bacteria.The water supply used during the manufacturing and testing processes was found to be free of bacteria (negative result for pseudomonas presence).It was confirmed that the swabs taken from cold/hot inlets, tap and filter were negative.Based on the review of previous complaints, we (arjohuntleigh) noticed different causes of pseudomonas aeruginosa developing such as for example: contamination of the customer's water installation, neglected maintenance of the device.In this case, we are not able to identify the cause of alleged contamination.General conclusion of root cause analysis is that many sources of the bacteria might be defined because the pseudomonas is extremely common bacteria that is present in moist environments such as soil, water, sinks and showers and often found in spas or purified water system operators.Pseudomonas grows in water and thrives at warm temperatures.It grows quickest if the water is allowed to sit without movement.To guarantee a reduction of the contamination long term, the device owner, who was provided with microbiological formation prevention procedure (included in the instructions for use 04.Az.00_12gb dated on january 2015, which was delivered with the device) is obligated to: " make sure that the water circulates in the bath and the shower on a daily basis even if the bathtub is not used; and particular to make sure to remove any water that may be left behind in the hose.Let the water flow approximately 5 minutes before the first bath of the day.Clean and disinfect the bathtub according to the ifu before the first bath of the day and after the bath of each patient." in summary, the bath was alleged contaminated with pseudomonas aeruginosa and from that perspective the device was not performing to manufacturer specification.The complaint was reported due to indicated microorganism on the bath system.The arjohuntleigh bath malibu was confirmed to be not a source of the pseudomonas aeruginosa bacteria.No adverse event was reported.The results of the investigation performed enable us to determine that allegation reported does not compromise patient safety and is not likely to cause or contribute to a death, serious injury or deterioration in the state of health.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MALIBU
Type of Device
BATH, HYDRO-MASSAGE
Manufacturer (Section D)
ARJOHUNTLEIGH POLSKA SP. Z O.O.
ul. ks. piotra wawrzyniaka 2
komorniki, 62-05 2
PL  62-052
Manufacturer (Section G)
ARJOHUNTLEIGH POLSKA SP. Z O.O.
ul. ks. piotra wawrzyniaka 2
komorniki, 62-05 2
PL   62-052
Manufacturer Contact
kinga stolinska
ul. ks. piotra wawrzyniaka 2
komorniki, 62-05-2
PL   62-052
98282467
MDR Report Key6518007
MDR Text Key73613239
Report Number3007420694-2017-00097
Device Sequence Number1
Product Code ILJ
Combination Product (y/n)N
Reporter Country CodeUK
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,user f
Reporter Occupation Other
Remedial Action Repair
Type of Report Initial,Followup,Followup,Followup,Followup
Report Date 11/30/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator No Information
Device Model NumberAZR33116-GB
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? No
Was the Report Sent to FDA? Yes
Date Report Sent to FDA11/30/2017
Distributor Facility Aware Date03/28/2017
Device Age6 MO
Event Location Nursing Home
Date Report to Manufacturer11/30/2017
Initial Date Manufacturer Received 03/28/2017
Initial Date FDA Received04/25/2017
Supplement Dates Manufacturer ReceivedNot provided
03/28/2017
10/05/2017
10/05/2017
Supplement Dates FDA Received05/23/2017
07/18/2017
10/31/2017
11/30/2017
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured09/30/2016
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Unknown
Patient Sequence Number1
Patient Outcome(s) Other;
-
-