• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: WARSAW ORTHOPEDICS BRYAN CERVICAL DISC SYSTEM; PROSTHESIS, INTERVERTEBRAL DISC

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

WARSAW ORTHOPEDICS BRYAN CERVICAL DISC SYSTEM; PROSTHESIS, INTERVERTEBRAL DISC Back to Search Results
Catalog Number 6474525
Device Problem Mechanical Problem (1384)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 05/23/2017
Event Type  malfunction  
Manufacturer Narrative
Neither the device nor films of applicable imaging studies were returned to the manufacturer for evaluation.Therefore, we are unable to determine the definitive cause of the reported event.
 
Event Description
Patient demographics: gender: female it was reported that during surgery, the cutter malfunctioned.It was unknown whether the gears were sheared or if it was faulty to begin with.The product came in contact with the patient.No patient complications were reported.
 
Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Manufacturer Narrative
Product analysis: instrument unable to be disassembled without damage.Functional evaluation found operation of cutter operable, but with intermittent slippage and jamming of internal gear and pinion, consistent with the -03 mill gear and -05 mill pinion interfacing features with significant material wear.This instrument is a single-use instrument.The above observations are consistent with anticipated wear.If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BRYAN CERVICAL DISC SYSTEM
Type of Device
PROSTHESIS, INTERVERTEBRAL DISC
Manufacturer (Section D)
WARSAW ORTHOPEDICS
2500 silveus crossing
warsaw IN 46582
Manufacturer (Section G)
WARSAW ORTHOPEDICS
2500 silveus crossing
warsaw IN 46582
Manufacturer Contact
stacie ziemba
1800 pyramid place
memphis, TN 38132
9013963133
MDR Report Key6649421
MDR Text Key77832801
Report Number1030489-2017-01576
Device Sequence Number1
Product Code MJO
UDI-Device Identifier00613994363817
UDI-Public00613994363817
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P060023
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Reporter Occupation Physician
Type of Report Initial,Followup,Followup
Report Date 10/24/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date08/07/2023
Device Catalogue Number6474525
Device Lot NumberEM15F058
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/28/2017
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 05/23/2017
Initial Date FDA Received06/19/2017
Supplement Dates Manufacturer Received05/23/2017
09/29/2017
Supplement Dates FDA Received10/05/2017
10/24/2017
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured08/07/2015
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-