• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ARTHREX, INC. TIGHTROPE, ABS, IMPLANT; PIN, FIXATION, SMOOTH

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ARTHREX, INC. TIGHTROPE, ABS, IMPLANT; PIN, FIXATION, SMOOTH Back to Search Results
Catalog Number AR-1588TN
Device Problems Device Operates Differently Than Expected (2913); Physical Property Issue (3008)
Patient Problem Complaint, Ill-Defined (2331)
Event Date 05/28/2017
Event Type  Injury  
Manufacturer Narrative
Patient demographics (age at time of event, date of birth, gender, weight) were requested but not provided.No further patient information was provided at the time of this report or made available in response to follow-up communication.No additional adverse consequences have been reported from this event.This device is used for treatment.The contribution of the device to the reported event could not be determined as the device was not returned for evaluation therefore the complainant's event could not be verified.The cause of the event could not be determined from the information available and without device evaluation.Device history record review revealed nothing relevant to this event.This is the first complaint of this type for this part/lot combination.The potential cause(s) of this event will be communicated to the event reporter.If additional relevant information is received, a follow-up report will be submitted.
 
Event Description
It was originally reported that after tightening the tibial side while extending the patient leg, the loop cut into two parts.After finishing the case the threads holding the button ripped and the surgeon was stuck with a short graft for almost two hours trying to cut the femoral button so he can release the graft and repeat the case.The acl reconstruction using all inside technique was performed.After that the surgeon used a different device with part no.: ar-1588rt.Additional information obtained 8 june 2017: the surgeon prepared the graft using an rt tightrope and abs tightrope for the tibia.Graft was a size 11.Both tendons were harvested.Instead of a flip cutter surgeon used and ar-1595t to open the eyelet drill pin for the femur and the tibial cortex was blown out with a drill bit.After passing the graft and shortening the femoral tightrope surgeon began shortening the tibial abs tightrope.All looked fine until surgeon started to probe the graft which was lax.Surgeon went back to the tibial to retighten the tightrope and it was found torn.The graft was short inside the tunnel so surgeon cut the femoral button to release the whole graft which took an hour.The same graft was prepared again and it was fixed with an rt tightrope in the femur and an 11 peek screw in the tibia.Post op testing was fine, new graft looked fine.Additional information obtained 16 june 2017: it wasn't an all inside the surgeon, penetrated the tibial cortex using a drill bit.Neither the tightrope suture material nor the button were left in the patient.
 
Manufacturer Narrative
Patient demographics (age at time of event, date of birth, gender, weight) were requested but not provided.No further patient information was provided at the time of this report or made available in response to follow-up communication.No additional adverse consequences have been reported from this event.This device is used for treatment.This is a follow-up submission due to device evaluation.Device history record review revealed nothing relevant to this event.Complaint confirmed.The evaluation revealed the returned tightrope suture construct to be broken and frayed.No problems found on returned abs tightrope button.The exact root cause was unable to be determined.This is the first complaint of this type for this part/lot combination.The potential cause(s) of this event will be communicated to the event reporter.If additional relevant information is received, a follow-up report will be submitted.
 
Event Description
It was originally reported that after tightening the tibial side while extending the patient leg, the loop cut into two parts.After finishing the case the threads holding the button ripped and the surgeon was stuck with a short graft for almost two hours trying to cut the femoral button so he can release the graft and repeat the case.The acl reconstruction using all inside technique was performed.After that the surgeon used a different device with part no.: ar-1588rt.Additional information obtained 8 june 2017: the surgeon prepared the graft using an rt tightrope and abs tightrope for the tibia.Graft was a size 11.Both tendons were harvested.Instead of a flip cutter surgeon used and ar-1595t to open the eyelet drill pin for the femur and the tibial cortex was blown out with a drill bit.After passing the graft and shortening the femoral tightrope surgeon began shortening the tibial abs tightrope.All looked fine until surgeon started to probe the graft which was lax.Surgeon went back to the tibial to retighten the tightrope and it was found torn.The graft was short inside the tunnel so surgeon cut the femoral button to release the whole graft which took an hour.The same graft was prepared again and it was fixed with an rt tightrope in the femur and an 11 peek screw in the tibia.Post op testing was fine, new graft looked fine.Additional information obtained 16 june 2017: it wasn't an all inside the surgeon, penetrated the tibial cortex using a drill bit.Neither the tightrope suture material nor the button were left in the patient.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TIGHTROPE, ABS, IMPLANT
Type of Device
PIN, FIXATION, SMOOTH
Manufacturer (Section D)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer (Section G)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer Contact
vik bajnath, sr mdr analyst
1370 creekside boulevard
naples, FL 34108-1945
8009337001
MDR Report Key6692691
MDR Text Key79258568
Report Number1220246-2017-00244
Device Sequence Number1
Product Code HTY
UDI-Device Identifier00888867019706
UDI-Public00888867019706
Combination Product (y/n)N
Reporter Country CodeGM
PMA/PMN Number
K110123
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation Medical Equipment Company Technician/Representative
Type of Report Initial,Followup
Report Date 08/21/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Expiration Date09/01/2020
Device Catalogue NumberAR-1588TN
Device Lot Number300472
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer07/25/2017
Is the Reporter a Health Professional? No
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 06/16/2017
Initial Date FDA Received07/07/2017
Supplement Dates Manufacturer Received06/16/2017
Supplement Dates FDA Received08/16/2017
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured10/01/2015
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Other;
-
-