MAUDE Adverse Event Report: MEDTRONIC MED REL MEDTRONIC PUERTO RICO ENTERRA; INTESTINAL STIMULATOR

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MEDTRONIC MED REL MEDTRONIC PUERTO RICO ENTERRA; INTESTINAL STIMULATOR Back to Search Results
Model Number 3116
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Low Blood Pressure/ Hypotension (1914); Nausea (1970); Pain (1994); Renal Failure (2041); Scar Tissue (2060); Urinary Retention (2119); Discomfort (2330); Complaint, Ill-Defined (2331); Reaction (2414); Cognitive Changes (2551); Lethargy (2560); Test Result (2695)
Event Date 04/09/2009
Event Type  Injury  
Manufacturer Narrative
A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Event Description
The patient reported that on (b)(6) 2009, the day after they were implanted, they had so much scar tissue that their kidney shut down.They indicated that they were in the icu.There were no further complications reported as a result of this event.The indication for use was gastric stimulation.
 
Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event Description
Additional information received from the patient indicated that during the implant surgery, their kidneys shut down.They woke up in the icu, and the surgeon told them they were in the icu due to their kidneys shutting down.The surgeon stated that there was more scar tissue in the abdomen cavity than he had anticipated.This caused the implant to be a "disaster going in" and the surgery to last a lot longer.It was supposed to last 2-3 hours, but ended up taking 9 hours.The patient stated that the surgeon should have backed out when they encountered that much scar tissue.There were no further complications reported as a result of this event.
 
Manufacturer Narrative
Patient code of (b)(4) was removed as it no longer applied to this event.If information is provided in the future, a supplemental report will be issued.
 
Event Description
Additional information received from the healthcare provider (hcp) indicated that the scar tissue was not related to the patient's underlying condition.From the operative report on (b)(6)2009, it was noted that there were moderate amounts of adhesions in the right upper quadrant secondary to an open cholecystectomy.During the procedure, moderate amounts of adhesions were encountered involving the distal stomach and prepyloric regions.The adhesions were bluntly and sharply divided with the use of electrocautery, identifying the pylorus measuring approximately 10 cm.The leads were sutured in place, connected to the generator, and placed in the pocket.Impedance values were 579 before and after the system was placed in the pocket.Normal settings were accepted.It was noted that the patient tolerated the procedure well, and was taken to recovery in stable condition.In the discharge summary on (b)(6)2009, it was indicated that the patient's secondary diagnosis included: nonalcoholic steatohepatitis, obstructive sleep apnea, gastroesophageal reflux disease, hypothyroidism, bipolar disorder, osteoarthritis, posttraumatic stress disorder, obesity, and psoriasis.Medications included: lantus insulin, seroquel, trazodone, ambien, cymbalta, celexa, valium, synthroid, and zofran.The abdominal exam showed generalized tenderness even on light palpation.The patient had surgical lesions on their hands.Lab work showed a wbc count of 5, h and h of 12.5/36.8,platelets 214,000, bun and creatinine 10/0.8, sodium 141, potassium 3.9, alkaline phosphatase elevated to 165, sgot up to 65, sgpt up to 51, total bilirubin was 0.6, magnesium was 2.3, lipase 29, and the urinalysis was essentially negative.A chest x-ray showed minimal linear scarring or atelectasis in the left lower lung.Ekg showed normal sinus rhythm with nonspecific st-t wave abnormalities.When this was compared to a prior ekg tracing, no changes were found.It was noted that a hcp performed an intraoperative gastroscopy to verify gastric leads did not penetrate the stomach.Postoperatively, the patient was continued on iv fluids and allowed same prehospital medications.The patient's glucose was controlled with an insulin sliding scale, they were given pepcid for ulcer prevention, and were give zofran for nausea.The patient was allowed dilaudid by mouth for pain control.The following day, the patient was started on lovenox for additional deep vein thrombosis prophylaxis.They developed an episode of decreased mental status and hypotension that required transfer to the critical care unit.Workup was essentially negative including troponins, blood glucose, ekg, and chest x-ray.A foley catheter was placed.Repeat stat blood labs were essentially normal.The hcp thought that the patient's seroquel dosage was too high, and they were lethargic from this and the combination of their pain medications.The pain medications and seroquel were withheld.Over the next several days, the patient's mental status returned to baseline.It was noted that the patient was well enough for discharge, afebrile, tolerating a regular diet, urinating with the foley catheter out, and ambulating.The abdominal incision was clear with minimal tenderness.The patient was instructed regarding diet, activity, and wound care.A prescription was written for dilaudid 2 mg by mouth, every 6 hours, as needed.The discharge medications included: celexa, valium, cymbalta, lantus insulin, synthroid, seroquel, trazodone, ambien, dilaudid, and prilosec.There were no further complications reported as a result of this event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ENTERRA
Type of Device
INTESTINAL STIMULATOR
Manufacturer (Section D)
MEDTRONIC MED REL MEDTRONIC PUERTO RICO
road 31, km. 24, hm 4
ceiba norte industrial park
juncos PR 00777
Manufacturer (Section G)
MEDTRONIC MED REL MEDTRONIC PUERTO RICO
road 31, km. 24, hm 4
ceiba norte industrial park
juncos PR 00777
Manufacturer Contact
lisa woodward clark
7000 central avenue ne rcw215
minneapolis, MN 55432
7635263920
MDR Report Key6763735
MDR Text Key81716549
Report Number3004209178-2017-16156
Device Sequence Number1
Product Code LNQ
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
H990014
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type consumer,health professional
Reporter Occupation Other
Type of Report Initial,Followup,Followup
Report Date 10/10/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Expiration Date08/14/2010
Device Model Number3116
Device Catalogue Number3116
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Initial Date Manufacturer Received 07/25/2017
Initial Date FDA Received08/03/2017
Supplement Dates Manufacturer Received08/14/2017
09/12/2017
Supplement Dates FDA Received09/12/2017
10/10/2017
Date Device Manufactured02/24/2009
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Life Threatening;
Patient Age50 YR
Patient Weight141
-
-