Model Number 294774
Device Problems Thermal Decomposition of Device (1071); Smoking (1585); Out-Of-Box Failure (2311)
Patient Problem No Patient Involvement (2645)
Event Date 08/21/2017
Event Type  malfunction  
Manufacturer Narrative
(b)(4).The printed circuit board assembly (pcba) was replaced.The unit operated to the manufacturer¿s specifications.The defective part is being evaluated by the manufacturer.
 
Event Description
The service repair technician (srt) reported that out of box during testing of the device the screen went black and smoke was smoke coming out of the monitor.There was no patient involvement.
 
Manufacturer Narrative
During laboratory analysis, the product surveillance technician (pst) observed that c57 and c8 shorted.C57 and c8 are used in the 12 volt (v) direct current (dc) circuit of +12vtlswitch and is also tied in the switching of alternating current (ac) power to +12v dc battery power.If additional information becomes available on this complaint that would alter the facts and/or conclusion, a supplemental report will be filed accordingly.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CDI BLOOD PARAMETER MONITORING SYSTEM 500
Type of Device
MONITOR, BLOOD-GAS, ON-LINE, CARDIOPULMONARY BYPASS-CDI BPM SYSTEM 500
Manufacturer (Section D)
TERUMO CARDIOVASCULAR SYSTEMS CORPORATION
6200 jackson road
ann arbor MI 48103
Manufacturer Contact
katie hoyt
6200 jackson road
ann arbor, MI 48103
7346634145
MDR Report Key6861376
MDR Text Key86120794
Report Number1828100-2017-00415
Device Sequence Number1
Product Code DRY
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K133658
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 10/26/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Model Number294774
Device Catalogue Number294774
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? No
Initial Date Manufacturer Received 08/21/2017
Initial Date FDA Received09/13/2017
Supplement Dates Manufacturer Received10/03/2017
Supplement Dates FDA Received10/26/2017
Was Device Evaluated by Manufacturer? Yes
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
-
-