Model Number N/A
Device Problem Device Slipped (1584)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Type  malfunction  
Manufacturer Narrative
(b)(4).Customer has indicated that the product is in process of being returned to zimmer biomet for investigation.Once the investigation has been completed, a follow-up mdr will be submitted.Multiple mdr reports were filed for this event, please see associated reports: 0001822565-2017-06708 and 0001822565-2017-06709.
 
Event Description
It was reported that during an open reduction internal fixation procedure of the femur, the guide wire instrument did not grip properly.Another instrument from another tray was utilized to complete the procedure.No adverse events have been reported as a result of the malfunction.
 
Manufacturer Narrative
Complaint sample was evaluated and the reported event was confirmed.Visual inspection noted scratch marks on the impaction surface.No fracture was seen on the spring mechanism.The 3.0 mm hole exhibits heavy gauging and wear indicative of use.The wear on the holes leads to insufficient gripping of guide wires.A functional check was performed with a mating guide wire, and the 3.0 mm hole failed to securely grip guide wire.Device history record was reviewed and no discrepancies relevant to the reported event were found.Review of the complaint history determined that no further action is required.Based on the information available, the root cause can be determined as normal wear during the instrument¿s field life.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ZIMMER NATURAL NAIL GUIDE WIRE GRIPPER
Type of Device
PASSER, WIRE
Manufacturer (Section D)
ZIMMER BIOMET, INC.
56 e. bell drive
warsaw IN 46582
Manufacturer (Section G)
ZIMMER BIOMET, INC.
56 e. bell drive
warsaw IN 46582
Manufacturer Contact
christina arnt
56 e. bell dr.
warsaw, IN 46582
5745273773
MDR Report Key6903757
MDR Text Key87779068
Report Number0001822565-2017-06709
Device Sequence Number1
Product Code HXI
Combination Product (y/n)N
Reporter Country CodeCA
PMA/PMN Number
PEXEMPT
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 02/15/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Physician
Device Model NumberN/A
Device Catalogue Number00249001200
Device Lot Number63017696
Other Device ID NumberN/A
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/15/2018
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 08/31/2017
Initial Date FDA Received09/29/2017
Supplement Dates Manufacturer Received02/14/2018
Supplement Dates FDA Received02/15/2018
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured03/23/2015
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Removal/Correction NumberN/A