BARD PERIPHERAL VASCULAR, INC. ATLAS PTA BALLOON DILATATION CATHETER; CATHETER, ANGIOPLASTY, PERIPHERAL, TRANSLUMINAL Back to Search Results
Model Number AT75186
Device Problems Peeled/Delaminated (1454); Unraveled Material (1664)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 09/06/2017
Event Type  malfunction  
Manufacturer Narrative
No hospital/medical records or medical images have been made available to the manufacturer.As the lot number for the device was provided, a review of the device history records is currently being performed.The device has been returned to the manufacturer for evaluation.The investigation of the reported event is currently underway.The information provided by bard represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bard.
 
Event Description
It was reported that following a venous compression procedure, after removal of the device from the patient, frayed material was identified on the balloon.The procedure was concluded, and no further treatment was provided.There was no reported patient injury.
 
Manufacturer Narrative
Manufacturing review: the device history records were reviewed with special attention to the raw materials, subassemblies, manufacturing process and quality control testing.This lot met all release criteria.There was nothing found to indicate there was a manufacturing related cause for this event.This is the only complaint reported to date for this lot number and failure mode.Conclusion: the device was returned for evaluation.A visual inspection found fibers to be unraveled along the length of the device.Additionally, the outer pebax was also found to be peeled on the balloon.Therefore, the investigation is confirmed for both unraveled fibers and peeled pebax.The investigation is unconfirmed for the reported frayed fibers, as it is likely the user perceived the unraveled fibers as frayed.Per the reported event details, the device was used to post-dilate three stents during the procedure.Therefore, it is possible that stent related issues contributed to the identified issues.However, the definitive root cause for the rupture could not be determined based upon the available information.Labeling review: the current ifu (instructions for use) states: warnings: when the catheter is exposed to the vascular system, it should be manipulated while under high-quality fluoroscopic observation.Do not advance or retract the catheter unless the balloon is fully deflated.If resistance is met during manipulation, determine the cause of the resistance before proceeding.Applying excessive force to the catheter can result in tip breakage or balloon separation.Do not exceed the rbp recommended for this device.Balloon rupture may occur if the rbp rating is exceeded.To prevent over pressurization, use of a pressure monitoring device is recommended.Precautions: if resistance is felt during post procedure withdrawal of the catheter, it is recommended to remove the balloon catheter and guidewire/introducer sheath as a single unit.Use of the atlas pta dilatation catheter: apply negative pressure to fully evacuate fluid from the balloon.Confirm that the balloon is fully deflated under fluoroscopy.While maintaining negative pressure and the position of the guidewire, withdraw the deflated dilatation catheter over the wire through the introducer sheath.Use of a gentle counterclockwise motion may be used to help facilitate catheter removal through the introducer sheath.
 
Event Description
It was reported that following a venous compression procedure, after removal of the device from the patient, frayed material was identified on the balloon.The procedure was concluded, and no further treatment was provided.There was no reported patient injury.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ATLAS PTA BALLOON DILATATION CATHETER
Type of Device
CATHETER, ANGIOPLASTY, PERIPHERAL, TRANSLUMINAL
Manufacturer (Section D)
BARD PERIPHERAL VASCULAR, INC.
1625 w 3rd st.
tempe AZ 85281
Manufacturer (Section G)
C.R. BARD, INC. (GFO)
289 bay road
queensbury NY 12804
Manufacturer Contact
judith ludwig
1625 w 3rd st.
tempe, AZ 85281
4803032689
MDR Report Key6930366
MDR Text Key90040288
Report Number2020394-2017-01298
Device Sequence Number1
Product Code LIT
UDI-Device Identifier00801741062506
UDI-Public(01)00801741062506
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K120971
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 10/20/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date07/28/2020
Device Model NumberAT75186
Device Catalogue NumberAT75186
Device Lot NumberGFBV0706
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/25/2017
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 09/12/2017
Initial Date FDA Received10/09/2017
Supplement Dates Manufacturer Received10/19/2017
Supplement Dates FDA Received10/20/2017
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured08/21/2017
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Age43 YR
Patient Weight97
-
-