Model Number 10-85-00
Device Problems Display or Visual Feedback Problem (1184); Calibration Problem (2890); Device Sensing Problem (2917)
Patient Problem No Patient Involvement (2645)
Event Date 09/08/2017
Event Type  malfunction  
Manufacturer Narrative
There was no patient involvement.Livanova (b)(4) manufactures the s5 double head pump.The incident occurred in (b)(4).This medwatch report is being filed on behalf of livanova (b)(4).A livanova field service representative was dispatched to the facility to investigate.The service representative confirmed the reported issue and identified dirt between the display and the rubber seal of the housing, which could cause the reported issue.The touch screen was replaced and the software was updated.Subsequent testing did not identify further issues and the unit was returned to service.A review of the dhr did not identify any deviations or non-conformities relevant to the reported issue.The replaced parts have been scrapped.No further evaluation can be performed.The root cause is believed to be the penetration of dirt and dust into the device.Replaced device has been scrapped.
 
Event Description
Livanova (b)(4) received a report that the touch screen of the s5 double head pump was found to be out of calibration during set-up.When making selections on the screen, the device would respond 4cm to the right of where the screen was touched.There was no patient involvement.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
S5 DOUBLE HEAD PUMP
Type of Device
CONSOLE, HEART-LUNG MACHINE, CARDIOPULMONARY BYPASS
Manufacturer (Section D)
LIVANOVA DEUTSCHLAND
lindberghstr. 25
munich 80939
GM  80939
Manufacturer (Section G)
LIVANOVA DEUTSCHLAND
lindberghstr. 25
munich 80939
GM   80939
Manufacturer Contact
joan ceasar
14401 w. 65th way
arvada, CO 80004
2812287260
MDR Report Key6940574
MDR Text Key90228509
Report Number9611109-2017-00799
Device Sequence Number1
Product Code DWB
Combination Product (y/n)N
Reporter Country CodeNL
PMA/PMN Number
K071318
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type health professional
Reporter Occupation Health Professional
Remedial Action Other
Type of Report Initial
Report Date 10/11/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number10-85-00
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 09/11/2017
Initial Date FDA Received10/11/2017
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured10/26/2005
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
-
-