• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: TERUMO CARDIOVASCULAR SYSTEMS CORPORATION SHUNT SENSOR SYS500; BLOOD GAS MONITOR

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

TERUMO CARDIOVASCULAR SYSTEMS CORPORATION SHUNT SENSOR SYS500; BLOOD GAS MONITOR Back to Search Results
Model Number CDI510H
Device Problem Leak/Splash (1354)
Patient Problem No Patient Involvement (2645)
Event Date 11/14/2017
Event Type  malfunction  
Manufacturer Narrative
Terumo has not received the device for evaluation; therefore, the investigation has yet to be completed.Terumo plans on submitting a follow-up report when the investigation is complete and when more information becomes available.For this reason, terumo references evaluation conclusion.(b)(4).Results: results pending completion of evaluation.Conclusions: conclusion not yet available-evaluation in progress.
 
Event Description
The user facility reported to terumo cardiovascular that prior to cardiopulmonary bypass, during prime, the shunt sensor leaked.No patient involvement as this occurred during prime.Product was changed out.Procedure was completed successfully.
 
Manufacturer Narrative
This follow-up report is submitted to fda in accord with applicable regulations ¿ and as indicated by terumo cardiovascular systems in the initial report submitted to the fda on december 7, 2017.All available information has been placed on file in quality management for appropriate tracking, trending, and follow-up.
 
Manufacturer Narrative
This follow-up report is submitted to fda in accord with applicable regulations.The returned sample was visually inspected for any anomalies, no white cap, no sparger and no buffer were present upon receiving.Upon closer look at the large blue vent cap, some crystallized white residue was noted between the threads.The large blue vent cap was found stuck and was not able to be tightened or loosened.The returned sample was leak tested by connecting with manometer and syringe, submerged and pressurized with air to around 406 mmhg, when it started to leak.After removing from the water bath, it was observed that the white residue was dissolved.An attempt to tighten the large luer vent cap, it was able to tightened up to half thread.It was leak tested again, pressurized up to 1023 mmhg for 30 seconds and no leaks were observed.Three samples from the 13 unopened units that were returned from the customer were visually inspected, leak tested and pressurized > 1000mmhg for 30 seconds.No anomalies or leaks were observed.The root cause for this event was determined as the large blue vent cap was not fully tightened either during setup of the circuit or after the gas calibration, when the large blue vent cap was loosened, it had not been retightened fully prior to use in the line, causing a leak from the cap.All available information has been placed on file in quality management for appropriate tracking, trending, and follow-up.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SHUNT SENSOR SYS500
Type of Device
BLOOD GAS MONITOR
Manufacturer (Section D)
TERUMO CARDIOVASCULAR SYSTEMS CORPORATION
125 blue ball road
elkton MD 21921
Manufacturer Contact
cathleen hargreaves
125 blue ball road
elkton, MD 21921
8002837866
MDR Report Key7094932
MDR Text Key94284273
Report Number1124841-2017-00246
Device Sequence Number1
Product Code DRY
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K972962
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Reporter Occupation Other
Type of Report Initial,Followup,Followup
Report Date 01/12/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date09/30/2018
Device Model NumberCDI510H
Device Catalogue NumberN/A
Device Lot NumberVM10CXX
Other Device ID Number(01)00699753160767
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer12/07/2017
Is the Reporter a Health Professional? No
Initial Date Manufacturer Received 11/15/2017
Initial Date FDA Received12/07/2017
Supplement Dates Manufacturer Received12/07/2017
01/11/2018
Supplement Dates FDA Received12/20/2017
01/12/2018
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured10/28/2017
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-