• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BECTON DICKINSON INFUSION THERAPY SYSTEMS INC. BD INSYTE¿ AUTOGUARD¿ BC SHIELDED IV CATHETER; INTRAVASCULAR CATHETER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BECTON DICKINSON INFUSION THERAPY SYSTEMS INC. BD INSYTE¿ AUTOGUARD¿ BC SHIELDED IV CATHETER; INTRAVASCULAR CATHETER Back to Search Results
Catalog Number 381023
Device Problem Fail-Safe Design Failure (1222)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 12/07/2017
Event Type  malfunction  
Manufacturer Narrative
No lot # provided.Medical device expiration date: unknown.Device manufacture date: unknown.A device evaluation is anticipated, but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.
 
Event Description
It was reported that the safety mechanism on a bd insyte¿ autoguard¿ bc shielded iv catheter did not function properly, leaving the needle exposed.There was no report of injury or medical interventions.
 
Manufacturer Narrative
Results: one sample unit was received for evaluation by our quality engineer team.Upon examination, the needle was observed to be partially retracted and damage was found on the grip and at the connection of the grip to the barrel.The needle was pushed and repositioned to the outer position, the button was depressed, and the retraction was unsuccessful.Although the review of the dhrs review are required for mdr¿s per cpr 071, a review could not be performed as the lot number was not provided.Conclusion: the root cause of the defect was determined to have occurred during the manufacturing process.Within the production zones, the plug probe and load barrel stations have the ability to become misaligned and produce the type of damage observed.Proper personnel have been notified of this incident.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD INSYTE¿ AUTOGUARD¿ BC SHIELDED IV CATHETER
Type of Device
INTRAVASCULAR CATHETER
Manufacturer (Section D)
BECTON DICKINSON INFUSION THERAPY SYSTEMS INC.
9450 south state street
sandy UT 84070
Manufacturer (Section G)
BECTON DICKINSON INFUSION THERAPY SYSTEMS INC.
9450 south state street
sandy UT 84070
Manufacturer Contact
brett wilko
9450 south state street
sandy, UT 84070
8015652845
MDR Report Key7152734
MDR Text Key96115859
Report Number1710034-2017-00503
Device Sequence Number1
Product Code FOZ
Combination Product (y/n)N
Reporter Country CodeJA
PMA/PMN Number
K110443
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,other,user facility
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 01/25/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Other
Device Catalogue Number381023
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/09/2018
Is the Reporter a Health Professional? No
Initial Date Manufacturer Received 12/07/2017
Initial Date FDA Received12/28/2017
Supplement Dates Manufacturer Received12/07/2017
Supplement Dates FDA Received01/29/2018
Was Device Evaluated by Manufacturer? Yes
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Other;
-
-