Model Number M0068318170
Device Problem Break (1069)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 10/12/2017
Event Type  malfunction  
Manufacturer Narrative
(b)(4).Analysis of the returned device revealed that the suture on the blue with white stripe dilator was broken.The dart was retrieved from behind the cage of the capio slim.The dart has a small amount of suture attached to it.Analysis also revealed that the dart on the blue dilator was caught as intended in the capio cage when actuated and there was no damage to the capio slim suture capturing device.A review of the device history record (dhr) confirmed that the device met all material, assembly, and product specifications at the time of release to distribution.The investigation concluded that this complaint is associated with a product that meets the design and manufacture specifications but due to anatomical/procedural factors encountered during the procedure, performance of the device was limited.The most probable root cause classification is operational context.
 
Event Description
It was reported to boston scientific corporation that an uphold¿ lite device was used during a sacrospinous ligament fixation procedure performed on (b)(6) 2017.According to the complainant, during procedure, the capio cage failed to catch the needle.The procedure was completed with another uphold¿ lite device.The patient's condition at the conclusion of the procedure was reported to be stable.This event has been deemed reportable based on the investigation results: the suture on the blue dilator is broken.The dart was retrieved from behind the cage of the capio slim.The dart has a small amount of suture attached to it.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UPHOLD¿ LITE
Type of Device
MESH, SURGICAL, SYNTHETIC, UROGYNECOLOGIC, FOR PELVIC ORGAN PROLAPSE, TRANSVAGIN
Manufacturer (Section D)
BOSTON SCIENTIFIC - MARLBOROUGH
100 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
BOSTON SCIENTIFIC - MARLBOROUGH
100 boston scientific way
marlborough MA 01752
Manufacturer Contact
nancy cutino
100 boston scientific way
marlborough, MA 01752
5086834000
MDR Report Key7155832
MDR Text Key96112942
Report Number3005099803-2017-03727
Device Sequence Number1
Product Code OTP
UDI-Device Identifier08714729839200
UDI-Public08714729839200
Combination Product (y/n)N
Reporter Country CodeTW
PMA/PMN Number
K122459
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation Physician
Type of Report Initial
Report Date 12/05/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date02/17/2020
Device Model NumberM0068318170
Device Catalogue Number831-817
Device Lot Number0000056829
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/31/2017
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 12/05/2017
Initial Date FDA Received12/29/2017
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured03/08/2017
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Age75 YR