DEPUY ORTHOPAEDICS INC US UNKNOWN HIP FEMORAL AUGMENT Back to Search Results
Catalog Number UNK HIP FEMORAL AUGMENT
Device Problem Difficult to Remove (1528)
Patient Problems Not Applicable (3189); No Code Available (3191)
Event Date 12/19/2017
Event Type  Injury  
Manufacturer Narrative
(b)(4).If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event Description
During the surgery to re-adjustment of the stem anteversion on (b)(6) 2017, it was reported that the taper lock between the stem / sleeve was robust so that it took more than 60 minutes to remove the stem.The surgery was completed by grasping the neck part of the stem with a pliers and pulled it out.No further information was provided by the hospital.
 
Manufacturer Narrative
(b)(4).Investigation summary: no device associated with this report was received for examination.The information received will be retained for potential series investigations if triggered by trend analysis, post market surveillance, or other events within the quality system.Depuy considers the investigation closed.Should additional information be received, the information will be reviewed and the investigation will be re-opened as necessary.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UNKNOWN HIP FEMORAL AUGMENT
Type of Device
HIP FEMORAL AUGMENT
Manufacturer (Section D)
DEPUY ORTHOPAEDICS INC US
700 orthopaedic drive
warsaw IN 46581 0988
Manufacturer (Section G)
DEPUY ORTHOPAEDICS INC US
700 orthopaedic drive
warsaw IN 46581
Manufacturer Contact
chad gibson
700 orthopaedic drive
warsaw, IN 46581-0988
5743725905
MDR Report Key7206018
MDR Text Key97772710
Report Number1818910-2018-51542
Device Sequence Number1
Product Code KWY
Combination Product (y/n)N
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Type of Report Initial,Followup
Report Date 12/19/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue NumberUNK HIP FEMORAL AUGMENT
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 12/19/2017
Initial Date FDA Received01/19/2018
Supplement Dates Manufacturer Received08/03/2018
Supplement Dates FDA Received08/29/2018
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
-
-