PENUMBRA, INC. POD PACKING COIL; HCG, KRD Back to Search Results
Catalog Number RBYPODJ60
Device Problems Detachment Of Device Component (1104); Mechanical Jam (2983)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 12/29/2017
Event Type  malfunction  
Manufacturer Narrative
The product was not returned for evaluation.Without the return of the device, the root cause of the problem cannot be determined.The manufacturing records for this lot were reviewed and did not reveal any outstanding discrepancies, design, or quality concerns.This report is associated with mfr report number: 3005168196-2018-00217.
 
Event Description
The patient was undergoing a coil embolization procedure using pod packing coils (podjs).During the procedure, the physician successfully deployed and detached a podj using a lantern delivery microcatheter (lantern).The second podj then became stuck within the lantern while being advanced, and when the physician attempted to retract it, the podj unintentionally detached.The physician therefore removed the non-penumbra guide catheter with the lantern and podj inside from the patient.The procedure was then completed using a new lantern, a new catheter, and additional ruby coils.It was reported that the physician believes the lantern might have moved back in the guide catheter, causing the podj to become stuck.There was no report of an adverse effect to the patient.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
POD PACKING COIL
Type of Device
HCG, KRD
Manufacturer (Section D)
PENUMBRA, INC.
one penumbra place
alameda CA 94502
Manufacturer (Section G)
PENUMBRA, INC.
one penumbra place
alameda CA 94502
Manufacturer Contact
veronica farris
one penumbra place
alameda, CA 94502
5107483200
MDR Report Key7219061
MDR Text Key98423647
Report Number3005168196-2018-00216
Device Sequence Number1
Product Code HCG
UDI-Device Identifier00814548017679
UDI-Public00814548017679
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K170852
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Reporter Occupation Physician
Type of Report Initial
Report Date 12/29/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Physician
Device Catalogue NumberRBYPODJ60
Device Lot NumberF80012
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 12/29/2017
Initial Date FDA Received01/25/2018
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured10/16/2017
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Age33 YR
-
-