• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ZIMMER MANUFACTURING B.V. ZIMMER MULTIPOLAR SHELL; HIP PROSTHESIS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ZIMMER MANUFACTURING B.V. ZIMMER MULTIPOLAR SHELL; HIP PROSTHESIS Back to Search Results
Model Number N/A
Device Problems Difficult to Insert (1316); Difficult To Position (1467)
Patient Problem No Information (3190)
Event Date 01/15/2018
Event Type  malfunction  
Manufacturer Narrative
(b)(4).Customer has indicated that the product is in process of being returned to zimmer biomet for investigation.Once the investigation has been completed, a follow-up mdr will be submitted.(b)(6).Concomitant medical products: item # 00500104426 bipolar liner lot # 63317577.Multiple mdr reports were filed for this event, please see associated reports: 0002648920-2018-00112, 00113.
 
Event Description
It was reported that during surgery, the liner and cup would not mate.The surgeon used alternative products, which decreased one size from the original size to complete the surgery.Attempts have been made, and no further information has been provided.
 
Event Description
No further event information available at the time of this report.
 
Manufacturer Narrative
Complaint sample was evaluated and the reported event was confirmed.As returned, the locking ring of the shell showed damage around the tabs.The liner was damaged / gouged in multiple locations.The markings and indentations on the outer radius of the liner are consistent with impaction attempts of the liner against the metal tabs of the shell's locking ring.A trial fit was performed - the devices assembled as intended.Device history record (dhr) was reviewed and no discrepancies were found.Root cause was unable to be determined.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ZIMMER MULTIPOLAR SHELL
Type of Device
HIP PROSTHESIS
Manufacturer (Section D)
ZIMMER MANUFACTURING B.V.
turpeaux industrial park
route #1 km 123.4 bldg #1
mercedita PR 00715
MDR Report Key7273815
MDR Text Key100429243
Report Number0002648920-2018-00112
Device Sequence Number1
Product Code KWY
Combination Product (y/n)N
PMA/PMN Number
PK833991
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Type of Report Initial,Followup
Report Date 01/28/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Physician
Device Model NumberN/A
Device Catalogue Number00500104400
Device Lot Number63767298
Other Device ID Number(01) 00889024115293
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer03/05/2018
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 01/22/2018
Initial Date FDA Received02/15/2018
Supplement Dates Manufacturer Received01/23/2019
Supplement Dates FDA Received01/29/2019
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-