Model Number 801041
Device Problems Leak/Splash (1354); Device Displays Incorrect Message (2591)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 02/05/2018
Event Type  malfunction  
Manufacturer Narrative
(b)(4).Per the user facility, this error message has occurred three times but are unsure of specific dates.
 
Event Description
It was reported that during set-up of the device for a cardiopulmonary bypass (cpb) procedure, there was a belt slip error message displayed.As a result, an alternative device was employed.The surgical procedure was completed successfully.There was no delay, no blood loss, nor adverse consequences to the patient.
 
Manufacturer Narrative
Evaluation is in progress, but not yet concluded.
 
Manufacturer Narrative
The reported complaint was confirmed.During laboratory analysis, the product surveillance technician (pst) observed the main bearing to be leaking grease on the encoder wheel and drive belt area of pump causing the belt to slip.The product will be sent to service to be brought to manufacturer¿s specifications before being returned to the customer.If additional information becomes available on this complaint that would alter the facts and/or conclusion, a supplemental report will be filed accordingly.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
LARGE (6) ROLLER PUMP FOR TERUMO ADVANCED PERFUSION SYSTEM 1
Type of Device
PUMP, BLOOD, CARDIOPULMONARY BYPASS, ROLLER TYPE ¿ 6 INCH ROLLER PUMP
Manufacturer (Section D)
TERUMO CARDIOVASCULAR SYSTEMS CORPORATION
6200 jackson road
ann arbor MI 48103
MDR Report Key7300376
MDR Text Key101489410
Report Number1828100-2018-00100
Device Sequence Number1
Product Code DWB
Combination Product (y/n)N
PMA/PMN Number
K131618
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Type of Report Initial,Followup,Followup
Report Date 05/16/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number801041
Device Catalogue Number801041
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer03/13/2018
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 02/05/2018
Initial Date FDA Received02/27/2018
Supplement Dates Manufacturer Received03/13/2018
04/26/2018
Supplement Dates FDA Received04/06/2018
05/16/2018
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-