Model Number 97714
Device Problems Energy Output To Patient Tissue Incorrect (1209); Inappropriate/Inadequate Shock/Stimulation (1574)
Patient Problems Fall (1848); Therapeutic Effects, Unexpected (2099); Complaint, Ill-Defined (2331); Electric Shock (2554)
Event Type  malfunction  
Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event Description
Information was received from a consumer regarding a patient with an implantable neurostimulator (ins) for spinal pain.It was reported that the patient had the device turned off for six months because it would ¿go off¿ unexpectedly and it was like the patient was getting tazed.The patient said it felt like a zapping sensation where he is getting tazed all over his body with the stimulator at full power.The patient said it would knock them on their butt.The patient said the issue started about a month after the rep reprogrammed the device.The first time it happened was when the patient was getting out of a chair and it caused him to fall back into the chair.The second time, the patient was out walking, and it almost caused him to fall and hit his head on the pavement.The patient turned the device off after this because it might cause him to have an accident and need to be hospitalized.The patient reached out to his healthcare provider (hcp) and the hcp speculated that it could be the leads.The patient confirmed he has not had any falls or trauma.The zapping and tazing sensation were considered sudden.No further complications were reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SURESCAN
Type of Device
STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF
Manufacturer (Section D)
MEDTRONIC PUERTO RICO OPERATIONS CO.
road 31, km. 24, hm 4
ceiba norte industrial park
juncos PR 00777
Manufacturer (Section G)
MEDTRONIC PUERTO RICO OPERATIONS CO.
road 31, km. 24, hm 4
ceiba norte industrial park
juncos PR 00777
Manufacturer Contact
lisa woodward clark
7000 central avenue ne rcw215
minneapolis, MN 55432
7635263920
MDR Report Key7320197
MDR Text Key101994266
Report Number3004209178-2018-04576
Device Sequence Number1
Product Code LGW
UDI-Device Identifier00643169109483
UDI-Public00643169109483
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P840001
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type consumer
Reporter Occupation Other
Type of Report Initial
Report Date 03/07/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date07/28/2017
Device Model Number97714
Device Catalogue Number97714
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Initial Date Manufacturer Received 03/05/2018
Initial Date FDA Received03/07/2018
Date Device Manufactured09/02/2016
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-