Model Number 10280959
Device Problem Insufficient Information (3190)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 03/21/2018
Event Type  malfunction  
Manufacturer Narrative
(b)(4).Siemens is conducting a thorough investigation of the reported events.As this event is under investigation, a root cause has not yet been determined.A supplement report will be filed upon completion of the investigation.
 
Event Description
It was reported to siemens that a malfunction occurred while operating the artis zeego system.During an interventional procedure the store monitor was not functional.The patient was safely removed from the system and transferred to an alternate system where the procedure was completed.We are unaware of any impact to the state of health of the patient involved.
 
Manufacturer Narrative
Siemens has completed an investigation of the reported event.The root cause could not be determined as the replaced ias pc was not returned for investigation.The investigation of the log files showed that the ias pc could not connect to the ivs pc through the high speed link network (netlink disconnect) resulting in a high speed link error displayed on the control monitor and the examination room monitor.According to the log files the user continued to use the system performing fluoroscopic imaging.But since the network connection between the ias pc and the ivs pc failed the "store fluoro" option was not available on the graphical user interface in the control room.Therefore the user could not store the scene.The replaced ias pc was not returned for investigation.The most probable cause for a high speed link error is a failure of the network port on ias pc.This was confirmed during a simulation of the reported issue.On the affected system the ias pc was replaced.No systematic issue in the field was identified.No corrective action in the installed base is planned based on the present event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ARTIS ZEEGO
Type of Device
SYSTEM, X-RAY, ANGIOGRAPHIC
Manufacturer (Section D)
SIEMENS HEALTHCARE GMBH
siemenstrasse 1
forcheim, 91301
GM  91301
MDR Report Key7402706
MDR Text Key104567061
Report Number3004977335-2018-22658
Device Sequence Number1
Product Code IZI
Combination Product (y/n)N
PMA/PMN Number
K073290
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Remedial Action Inspection
Type of Report Initial,Followup
Report Date 03/21/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number10280959
Was Device Available for Evaluation? Yes
Was the Report Sent to FDA? No
Distributor Facility Aware Date03/21/2018
Event Location Hospital
Date Report to Manufacturer03/21/2018
Initial Date Manufacturer Received 03/21/2018
Initial Date FDA Received04/06/2018
Supplement Dates Manufacturer Received07/16/2018
Supplement Dates FDA Received07/16/2018
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-