MAUDE Adverse Event Report: ALCON RESEARCH, LTD. - IRVINE TECHNOLOGY CENTER CONSTELLATION VISION SYSTEM; UNIT, PHACOFRAGMENTATION

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ALCON RESEARCH, LTD. - IRVINE TECHNOLOGY CENTER CONSTELLATION VISION SYSTEM; UNIT, PHACOFRAGMENTATION Back to Search Results
Model Number TABLETOP
Device Problem Unstable (1667)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 03/21/2018
Event Type  malfunction  
Manufacturer Narrative
Investigation, including root cause analysis, is in progress.A supplemental mdr will be filed as necessary in accordance with 21 cfr 803.56 when additional reportable information becomes available.(b)(4).
 
Event Description
A customer reported that there was chamber instability during the phacoemulsification phase and irrigation/aspiration.The procedure was completed without patient harm.
 
Manufacturer Narrative
Additional information has been provided.The company representative examined the system and was unable to duplicate any issue associated with the reported issue.The system was then tested and met all product specifications.Intraocular surgery has always been recognized to induce substantial intra-ocular pressure (iop) fluctuations, this is true for both anterior (i.E.Cataract surgery) and posterior segment (i.E.Vitrectomy) surgeries.Acute ocular hypotony is common during many intraocular surgeries.Intra-operatively, maintenance of eye pressure is a balance between infusion (irrigation) and extrusion (aspiration) with both parameters actively controlled by the surgeon and with the advent of iop control features, supported by vitrectomy/phacoemulsification machines.Hypotony (less than 5mmhg) is in fact fairly common in eye surgery that most eye surgeons anticipate this to occur during surgery.Surgeons have been trained to recognize and mitigate this by adjustment of the previously mentioned parameters be it manually or through the machine to adapt to what is being performed during surgery.As stated in the operators manual: ¿the closed loop system that adjusts iop cannot replace the standard of care in judging iop intraoperatively.The surgeon must continue the common practice of informally judging the following: finger palpation on the globe, tactile feedback of the surgical instruments, retinal vessel perfusion/pulsations, and presence of corneal edema.If the surgeon believes the iop is not responding to the system settings and is dangerously high, the surgeon can do one or more of the following as they deem appropriate in this situation (with care to avoid sudden hypotony): close the infusion stopcock, pinch the infusion line, remove the infusion line.¿ the operator¿s manual includes the warnings: good clinical practice dictates the testing for adequate irrigation, aspiration flow, and operation as applicable for each handpiece prior to entering the eye.Visually confirm that adequate infusion flow is occurring prior to attachment of the infusion cannula to the eye.The system was manufactured on may 31, 2016.Based on quality assurance assessment, the product met specifications at the time of release.The system was found to meet specifications; therefore, the root cause of the reported event cannot be determined conclusively.The manufacturer internal reference number is: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CONSTELLATION VISION SYSTEM
Type of Device
UNIT, PHACOFRAGMENTATION
Manufacturer (Section D)
ALCON RESEARCH, LTD. - IRVINE TECHNOLOGY CENTER
15800 alton parkway
irvine CA 92618
Manufacturer (Section G)
ALCON RESEARCH, LTD. - IRVINE TECHNOLOGY CENTER
15800 alton parkway
irvine CA 92618
Manufacturer Contact
bryan blake
6201 south freeway
mail stop ab2-6
fort worth, TX 76134
8176152230
MDR Report Key7432778
MDR Text Key105664877
Report Number2028159-2018-00762
Device Sequence Number1
Product Code HQC
Combination Product (y/n)N
Reporter Country CodeIT
PMA/PMN Number
K101285
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation Hospital Service Technician
Remedial Action Other
Type of Report Initial,Followup
Report Date 08/28/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberTABLETOP
Device Catalogue Number8065751150
Other Device ID Number380657511501
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 03/22/2018
Initial Date FDA Received04/16/2018
Supplement Dates Manufacturer Received08/03/2018
Supplement Dates FDA Received08/28/2018
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured05/31/2016
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
Patient Outcome(s) Other;
-
-