Model Number TABLETOP-JAPAN
Device Problems Air Leak (1008); Aspiration Issue (2883)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Type  malfunction  
Manufacturer Narrative
Investigation, including root cause analysis, is in progress.A supplemental mdr will be filed as necessary in accordance with 21 cfr 803.56 when additional reportable information becomes available.(b)(4).
 
Event Description
An ophthalmic surgeon reported that air got mixed in the aspiration tube during a procedure.Aspiration failure occurred during irrigation/aspiration.The procedure was completed without product replacement.There was no patient harm.
 
Manufacturer Narrative
The lot complaint history was reviewed, this is the second complaint for the finish goods lot; however, the first for this issue for this lot.The device history record shows the product was released per specifications.The returned sample was visually inspected and no obvious defects were found.A console representing the current software version was used to test the sample.The ball in the drip chamber¿s check valve moved freely per specification.The sample could prime and tune with the handpiece successfully.The irrigation and aspiration pressure were measured at multiple set points and met specifications.No message code appeared on the screen.Fluid flowed from the irrigation solution to the drain bag without any interfering.No leakage was detected from the pump elastomer or on the pump area of the fluidics module.No air mix or failure of aspiration was observed.Cleaning process was able to be performed after functional test was completed.The sample passed functionality.The root cause of the customer's complaint could not be established; the returned sample met specifications.After a thorough investigation of this complaint, it has been determined that this sample met specifications; therefore, no corrective action is required at this time.Quality assurance has reviewed this complaint and will continue to monitor data for evidence of adverse trending and take further action, as appropriate.The manufacturer internal reference number is: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CONSTELLATION VISION SYSTEM
Type of Device
UNIT, PHACOFRAGMENTATION
Manufacturer (Section D)
ALCON RESEARCH, LTD. - IRVINE TECHNOLOGY CENTER
15800 alton parkway
irvine CA 92618
MDR Report Key7534644
MDR Text Key109045179
Report Number2028159-2018-01082
Device Sequence Number1
Product Code HQC
Combination Product (y/n)N
PMA/PMN Number
K101285
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional
Remedial Action Other
Type of Report Initial,Followup
Report Date 08/15/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberTABLETOP-JAPAN
Device Catalogue Number8065751817
Other Device ID Number380657518173
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer05/24/2018
Initial Date Manufacturer Received 04/26/2018
Initial Date FDA Received05/22/2018
Supplement Dates Manufacturer Received07/25/2018
Supplement Dates FDA Received08/15/2018
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Treatment
CONSTELLATION SURGICAL PROCEDURE PAK
Patient Outcome(s) Other;
-
-