MAUDE Adverse Event Report: MEDTRONIC PUERTO RICO OPERATIONS CO. SURESCAN; STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MEDTRONIC PUERTO RICO OPERATIONS CO. SURESCAN; STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF Back to Search Results
Model Number 97714
Device Problems Energy Output To Patient Tissue Incorrect (1209); Device Displays Incorrect Message (2591); Charging Problem (2892); Communication or Transmission Problem (2896); Device Operates Differently Than Expected (2913)
Patient Problems Pain (1994); Therapeutic Effects, Unexpected (2099)
Event Date 12/01/2017
Event Type  malfunction  
Manufacturer Narrative
Date inaccurate, only the year is valid.If information is provided in the future, a supplemental report will be issued.
 
Event Description
Information was received from a consumer regarding a patient who was implanted with an implantable neurostimulator (ins) for non-malignant pain, degenerative disc disease and herniated disc pain.It was reported that their stimulator wasn't charging; the patient couldn't get the external device to charge their implant.They reported that they hadn't charged since last year to early this year.The reason for not charging was due to the fact that late last year to early this year their therapy was off but their legs started buzzing like it was on.They turned their therapy on, the therapy worked, and they then turned it off.The patient was receiving a "reposition antenna" message on their recharger and "poor communication" on their programmer.The patient was advised to follow up with their healthcare provider to address the likely overdischarge.No further complications reported.
 
Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event Description
Additional information received from the consumer.The patient further clarified the event by stating that they were hurting from the "strong sensation" because the ins turned on by itself.No further complications reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SURESCAN
Type of Device
STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF
Manufacturer (Section D)
MEDTRONIC PUERTO RICO OPERATIONS CO.
road 31, km. 24, hm 4
ceiba norte industrial park
juncos PR 00777
Manufacturer (Section G)
MEDTRONIC PUERTO RICO OPERATIONS CO.
road 31, km. 24, hm 4
ceiba norte industrial park
juncos PR 00777
Manufacturer Contact
lisa woodward clark
7000 central avenue ne rcw215
minneapolis, MN 55432
7635263920
MDR Report Key7560577
MDR Text Key109782863
Report Number3004209178-2018-12349
Device Sequence Number1
Product Code LGW
UDI-Device Identifier00643169109483
UDI-Public00643169109483
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P840001
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type consumer
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 06/21/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date02/28/2016
Device Model Number97714
Device Catalogue Number97714
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Initial Date Manufacturer Received 05/30/2018
Initial Date FDA Received06/01/2018
Supplement Dates Manufacturer Received06/14/2018
Supplement Dates FDA Received06/21/2018
Date Device Manufactured04/07/2015
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Age63 YR
-
-