• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BD MEDICAL (BD WEST) MEDICAL SURGICAL 5 ML BD POSIFLUSH¿ SP

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BD MEDICAL (BD WEST) MEDICAL SURGICAL 5 ML BD POSIFLUSH¿ SP Back to Search Results
Catalog Number 306574
Device Problem Physical Resistance (2578)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 05/29/2018
Event Type  malfunction  
Manufacturer Narrative
Date of event: unknown.The date received by manufacturer has been used for this field.A device evaluation is anticipated, but has not yet begun.Upon completion of the investigation and/or device history review, a supplemental report will be filed.
 
Event Description
It was reported that there was difficult plunger movement when using a 5 ml bd posiflush¿ sp.There was no report of exposure, injury or medical intervention.
 
Manufacturer Narrative
No samples displaying the condition reported are available for examination.Bd is unable to fully investigate this incident.No root cause can be determined as no samples were received.There was no documentation of issues for the complaint of batch 7264801 during this production run.This is the first complaint for the lot# 7264801 for the same defect or symptom.Investigation conclusion: possible the sustaining force was on the high side of the product spec inducing the symptom reported.
 
Event Description
It was reported that there was difficult plunger movement when using a 5 ml bd posiflush sp.There was no report of exposure, injury or medical intervention.
 
Event Description
It was reported that there was difficult plunger movement when using a 5 ml bd posiflush¿ sp.There was no report of exposure, injury or medical intervention.
 
Manufacturer Narrative
Investigation summary: this is the first complaint for the lot# 7264801 for the same defect or symptom.Two (2) samples were received for evaluation by one of our quality engineers.Both have no packaging flow wrap, the plunger rod-rubber stopper, the tip cap, the saline solution.The barrel label confirms the lot# 7264801.They were tested for sustaining force; one had 12.80n and the other 13.75n; the product specification is <20n.Samples were within specification therefore failure mode is not verified.While a definitive root cause could not be determined, it is possible that the sustaining force was on the high side of the product spec inducing the symptom reported.Investigation conclusion: possible the sustaining force was on the high side of the product spec inducing the symptom reported.(product spec for sustaining force <20n).
 
Event Description
It was reported that there was difficult plunger movement when using a 5 ml bd posiflush¿ sp.There was no report of exposure, injury or medical intervention.
 
Manufacturer Narrative
Correction: due to an it issue beginning on 7/3/2018, previously filed emdrs did not contain required fields.This supplemental emdr is filed to provide the following omitted fields: sex: unknown.Event attributed to: other.Device single use?: no.Device returned to manufacture: no.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
5 ML BD POSIFLUSH¿ SP
Type of Device
FLUSH
Manufacturer (Section D)
BD MEDICAL (BD WEST) MEDICAL SURGICAL
1852 10th avenue
columbus NE 68601
MDR Report Key7599083
MDR Text Key111450902
Report Number1911916-2018-00297
Device Sequence Number1
Product Code NGT
Combination Product (y/n)N
PMA/PMN Number
K011982
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,other,user facility
Type of Report Initial,Followup,Followup,Followup
Report Date 08/14/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Nurse
Device Expiration Date08/31/2020
Device Catalogue Number306574
Device Lot Number7264801
Initial Date Manufacturer Received 05/29/2018
Initial Date FDA Received06/13/2018
Supplement Dates Manufacturer Received05/29/2018
05/29/2018
05/29/2018
Supplement Dates FDA Received07/17/2018
07/19/2018
09/05/2018
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Outcome(s) Other;
-
-