Model Number 2AF283
Device Problem Kinked (1339)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 03/27/2018
Event Type  malfunction  
Manufacturer Narrative
Product event summary: the device was returned and analyzed.Visual inspection of the catheter showed no apparent issue.Smart chip verification showed that the catheter has been not used.Performance testing did not show any system notice.The catheter passed the deflection test as per specification.Dissection showed that guide wire lumen kink 1.6710 inches from the tip.The catheter failed the performance test due to kink on guide wire lumen.If information is provided in the future, a supplemental report will be issued.
 
Event Description
It was reported that during a cryoablation procedure, the mapping catheter would not go through the access port of the balloon catheter.The mapping catheter was replaced without resolve.The balloon catheter was then replaced with resolve.The case was completed with cryo.No patient complications have been reported as a result of this event.The balloon catheter was returned to the manufacturer, analyzed, and tested out of specification.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ARCTIC FRONT ADVANCE CARDIAC CRYOABLATION CATHETER
Type of Device
PERCUTANEOUS CATHETER INTENDED FOR TREATMENT OF ATRIAL FIBRILLATION
Manufacturer (Section D)
MEDTRONIC CRYOCATH LP
9000 autoroute transcanadienne
pointe-claire,qc H9R 5 Z8
CA  H9R 5Z8
Manufacturer (Section G)
MEDTRONIC CRYOCATH LP
9000 autoroute transcanadienne
pointe-claire,qc H9R 5 Z8
CA   H9R 5Z8
Manufacturer Contact
anne schilling
8200 coral sea st ne
mounds view, MN 55112
7635052036
MDR Report Key7612569
MDR Text Key111441593
Report Number3002648230-2018-00403
Device Sequence Number1
Product Code OAE
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P100010/S015
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative
Reporter Occupation Other
Type of Report Initial
Report Date 06/18/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date04/12/2018
Device Model Number2AF283
Device Catalogue Number2AF283
Device Lot Number83032
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer04/06/2018
Is the Reporter a Health Professional? No
Initial Date Manufacturer Received 05/24/2018
Initial Date FDA Received06/19/2018
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured04/12/2016
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-