TELEFLEX MEDICAL HUDSON CONCHA COLUMN SHELFPAK,PED PAR; HUMIDIFIER, RESPIRATORY GAS, ( Back to Search Results
Catalog Number 382-30
Device Problem Material Separation (1562)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 06/01/2018
Event Type  malfunction  
Manufacturer Narrative
(b)(4).A visual, dimensional, and functional inspection of the device involved in the complaint could not be conducted since the device or a picture of the alleged defect was not provided at the time of this report.A device history record review could not be conducted since the lot number was not provided.No conclusion can be established at this time based on the lack of device sample.It is necessary to have the device sample in order to perform a thorough investigation.Customer complaint cannot be confirmed.Root cause cannot be determined.No corrective actions can be assigned at this time.If the device sample becomes available this report will be updated with the evaluation results.
 
Event Description
Customer complaint alleges the "column top separated from column canister when therapist tried to remove from neptune heater".Alleged issue reported as occurred during use.It was reported there was no patient injury or consequence.It was reported the canister was not saved, but the top and circuit are available to return.
 
Manufacturer Narrative
(b)(4).The top side (gas portals) of a 382-30 low-compliance concha column and an unidentified infant breathing circuit were returned for evaluation.The complaint sample represents only a part of the whole low-compliance column and cannot be tested.The top plastic portal cap of the column has separated from the body of the column.The root cause of the damaged condition has been assigned to "damaged during use".Looking at the white piece of sealing tape used to bond the aluminum column to the plastic portal cap, the tape is torn with ragged edges indicating the top piece did not simply separate.There had to be a twisting/turning force to cause such a pattern on the tape.It is not known what might have caused the column to "jam" in the neptune, but significant force was applied to the plastic portal cap to create the ripping/tearing affect.The complaint has been confirmed.
 
Event Description
Customer complaint alleges the "column top separated from column canister when therapist tried to remove from neptune heater".Alleged issue reported as occurred during use.It was reported there was no patient injury or consequence.It was reported the canister was not saved, but the top and circuit are available to return.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
HUDSON CONCHA COLUMN SHELFPAK,PED PAR
Type of Device
HUMIDIFIER, RESPIRATORY GAS, (
Manufacturer (Section D)
TELEFLEX MEDICAL
research triangle park NC
MDR Report Key7625964
MDR Text Key111903626
Report Number1417411-2018-00044
Device Sequence Number1
Product Code BTT
Combination Product (y/n)N
PMA/PMN Number
K820878
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Type of Report Initial,Followup
Report Date 06/01/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number382-30
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer06/20/2018
Initial Date Manufacturer Received 06/01/2018
Initial Date FDA Received06/21/2018
Supplement Dates Manufacturer Received07/11/2018
Supplement Dates FDA Received07/17/2018
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Treatment
NEPTUNE HEATER; NEPTUNE HEATER; NEPTUNE HEATER
-
-