ZIMMER BIOMET, INC. SHELL WITH CLUSTER HOLES POROUS 48 MM O.D. SIZE GG FOR USE WITH GG LINERS; PROSTHESIS, HIP Back to Search Results
Model Number N/A
Device Problems Difficult to Insert (1316); Difficult To Position (1467)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 04/02/2018
Event Type  Injury  
Manufacturer Narrative
(b)(4).Concomitant medical products: 00875200832, liner elevated rim 32 mm i.D.Size gg for use with 48 mm o.D.Size gg shell, 63746657.(b)(6).Multiple mdr reports were filed for this event, please see associated reports: 0001822565-2018-03545.Customer has indicated that the product is in process of being returned to zimmer biomet for investigation.Once the investigation has been completed, a follow-up mdr will be submitted.
 
Event Description
It was reported that during the left total hip arthroplasty, after implanting the shell, the liner couldn't be seated in the shell.Subsequently the surgeon completed the surgery with a different shell and liner.Delay of 40 minutes was noted.Attempts have been made and additional information on the reported event is unavailable.
 
Event Description
No further event information available at the time of this report.
 
Manufacturer Narrative
Complaint sample was evaluated and the reported event was not confirmed.Damage in the form of gouges and scratched along the elevated rim of the liner and on the inner radius of the liner were noted.Nicks and scratches were noted on the shell near the elevated portion of the liner.Dhr was reviewed and no discrepancies relevant to the reported event were found.Root cause was unable to be determined.A summary of the investigation has been sent to the complainant.If any further information is found which would change or alter any conclusions or information, a supplemental report will be filed accordingly.Zimmer biomet will continue to monitor for trends.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SHELL WITH CLUSTER HOLES POROUS 48 MM O.D. SIZE GG FOR USE WITH GG LINERS
Type of Device
PROSTHESIS, HIP
Manufacturer (Section D)
ZIMMER BIOMET, INC.
56 e. bell drive
warsaw IN 46582
MDR Report Key7664523
MDR Text Key113251998
Report Number0001822565-2018-03546
Device Sequence Number1
Product Code LPH
Combination Product (y/n)N
PMA/PMN Number
PK151448
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Type of Report Initial,Followup
Report Date 02/05/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Physician
Device Model NumberN/A
Device Catalogue Number00875304801
Device Lot Number63716493
Other Device ID Number(10) 00889024150133
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer08/13/2018
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 06/13/2018
Initial Date FDA Received07/05/2018
Supplement Dates Manufacturer Received02/04/2019
Supplement Dates FDA Received02/05/2019
Is This a Reprocessed and Reused Single-Use Device? No
Removal/Correction NumberN/A
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
Patient Age68 YR
Patient Weight48
-
-