MAUDE Adverse Event Report: MEDIVANCE, INC. ¿ 1725056 ARCTIC SUN TEMPERATURE MANAGEMENT SYSTEM, ARCTICGEL PADS; ARCTIC SUN GEL PADS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MEDIVANCE, INC. ¿ 1725056 ARCTIC SUN TEMPERATURE MANAGEMENT SYSTEM, ARCTICGEL PADS; ARCTIC SUN GEL PADS Back to Search Results
Catalog Number 317-07
Device Problems Patient-Device Incompatibility (2682); Appropriate Term/Code Not Available (3191)
Patient Problems Hypoxia (1918); Pressure Sores (2326); Respiratory Failure (2484); Burn, Thermal (2530)
Event Date 08/14/2018
Event Type  Injury  
Manufacturer Narrative
The investigation is still in progress.Once the investigation is complete a supplemental report will be filed.The information provided by bard represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bard.
 
Event Description
It was reported that a patient experienced a thermal injury on the back of the thigh.It is unknown how the area was treated.The pads were put on for a short period of time before therapy was stopped, but the pads were left on.Therapy resumed and the skin injury was observed during the 6:00 am skin assessment on the following day.The patient cardiac arrested three times with a hypoxic injury and respiratory failure requiring intubation.The patient also had three vessel disease and went to the cath lab for stent placements.It is unknown if therapy was stopped for the procedure or if the patient was receiving therapy during that time.The patient also has a history of parkinson¿s disease with a brain implant.Per additional information received from the complaint via email on (b)(6) 2018: the wound care documentation from (b)(6) 2018 stated that the area on the posterior , distal right leg measured 5 x 3 x 0.1 cm.The area on the posterior left leg was 8.4 x.3.2 x.0.1-0.2 cm.The treatment for both areas was ag mesh to the wound beds which was changed every 3 days.Abdominal pads were placed for outer dressing and changed daily.There were 3 small abrasions on the right anterior knee which were cleansed with saline and covered with xeroform.The arctic sun treatment was discontinued.The pads had been on the patient for 2 days, however therapy was not continued for the full duration of those 2 days.The patient arrived hyperthermic with skin intact.
 
Manufacturer Narrative
The reported event was confirmed.Visual evaluation of the returned sample noted one arctic gel pad kit with four used pads.No original packaging was returned, and the hydrogel liner was covered in zippered sample bags to prevent sticking.Visual inspection of the pad surfaces noted blood and tissue remnants on two of the four pads, consistent with the reported event.The tissue remnants were dark brown in color with a red undertone.The pads were attached to an in-house arctic sun unit.Unobstructed flow was observed through all four pads.The water temperature was set at 10 c, 20 c, and 30 c to observe any "hot spots" on the pads.The flow was observed to be optimal for all four pads, with no observable portions of the pads at a significantly higher temperature than any other part of the pad.The adhesion of the pads could not be determined, as the pads were returned used and standard biohazard ppe prevents adhesion from being tested on skin.The device history record was reviewed and found nothing that could have caused or contributed to the reported event.The instructions for use was found adequate and states the following: " the arctic sun® temperature management system is intended for monitoring and controlling patient temperature in adult and pediatric patients of all ages.Contraindications.There are no known contraindications for the use of a thermoregulatory system.Do not place arcticgel¿ pads on skin that has signs of ulcerations, burns, hives or rash.While there are no known allergies to hydrogel materials, caution should be exercised with any patient with a history of skin allergies or sensitivities.Warning.Do not place arcticgel¿ pads over transdermal medication patches as warming can increase drug delivery, resulting in possible harm to the patient.Cautions.Federal law restricts this device to sale by or on the order of a physician.This product is to be used by or under the supervision of trained, qualified medical personnel.The clinician is responsible for determining the appropriateness of use of this device and the usersettable parameters, including water temperature, for each patient.For small patients (=30 kg) it is recommended to use the following settings: water temperature high limit =40°c (104°f); water temperature low limit =10°c (50°f); control strategy =2.It is recommended to use the patient temperature high and patient temperature low alert settings.Due to underlying medical or physiological conditions, some patients are more susceptible to skin damage from pressure and heat or cold.Patients at risk include those with poor tissue perfusion or poor skin integrity due to edema, diabetes, peripheral vascular disease, poor nutritional status or steroid or high dose vasopressor therapy.If accessible, examine the patient¿s skin under the arcticgel¿ pads often; especially those patients at higher risk of skin injury.Skin injury may occur as a cumulative result of pressure, time and temperature.Possible skin injuries include bruising, tearing, skin ulcerations, blistering, and necrosis.Do not place bean bags or other firm positioning devices under the arcticgel¿ pads.Do not place any positioning devices under the pad manifolds or patient lines.Do not allow urine, antibacterial solutions or other agents to pool underneath the arcticgel¿ pads.Urine and antibacterial agents can absorb into the pad hydrogel and cause chemical injury and loss of pad adhesion.Replace pads immediately if these fluids come into contact with the hydrogel.Do not place arcticgel¿ pads directly over an electrosurgical grounding pad.The combination of heat sources may result in skin burns.Carefully remove arcticgel¿ pads from the patient¿s skin at the completion of use.Aggressive removal or removal of cold pads from the patient¿s skin may result in skin tears.The arcticgel¿ pads are non-sterile for single patient use only.Do not place pads in the sterile field.If used in a sterile environment, pads should be placed according to the physician¿s directions, either prior to the sterile preparation or sterile draping.Do not reprocess or sterilize.Use pads immediately after opening.Do not store pads in opened pouch.Do not allow circulating water to contaminate the sterile field when lines are disconnected.The arcticgel¿ pads should not be punctured with sharp objects.Punctures will result in air entering the fluid pathway and may reduce performance.If warranted, use pressure relieving or pressure reducing devices under the patient to protect from skin injury.The arcticgel¿ pads are only for use with an arctic sun® temperature management system.The water content of the hydrogel affects the pad¿s adhesion to the skin and conductivity, and therefore, the efficiency of controlling patient temperature.Periodically check that pads remain moist and adherent.Replace pads when the hydrogel no longer uniformly adheres to the skin.Replacing pads at least every 5 days is recommended.If needed, place defibrillation pads between the arcticgel¿ pads and the patient¿s skin.Discard used arcticgel¿ pads in accordance with hospital procedures for medical waste.Directions for use arcticgel¿ pads are only for use with an arctic sun® temperature management system control module.See operators manual for detailed instructions on system use.Select the proper number, size and style pad for the patient size and clinical indication.However, the rate of temperature change and potentially the final achievable temperature is affected by pad surface area, patient size, pad placement and water temperature range.Best system performance will be achieved by using the maximum number and largest size pads.For patient comfort, the pads may be prewarmed using water temperature control mode (manual) prior to application.Place the pads on healthy, clean skin only.Remove any creams or lotions from patient¿s skin before pad application.Remove the release liner from each pad and apply to the appropriate area.The pads may be overlapped or folded adhesive-to-adhesive to achieve proper placement.The pads may be removed and reapplied if necessary.The pad surface must be contacting the skin for optimal energy transfer efficiency.Place pads to allow for full respiratory excursion.Attach the pad¿s line connectors to the patient line manifolds.Begin circulating water through the pads using either patient temperature control mode (automatic) or water temperature control mode (manual).If the pads fail to prime or a significant continuous air leak is observed in the pad return line, check connections, then if needed replace the leaking pad.Once the pads are primed, assure the flow rate displayed on the control panel is greater than 2.3 liters per minute, which is the minimum flow rate for a full pad kit.When finished, empty water from pads.Cold temperature increases the adhesiveness of the hydrogel.For ease of removal, leave pads on the patient for approximately 15 minutes to allow the hydrogel to warm.Slowly remove pads from the patient and discard.".
 
Event Description
It was reported that a patient experienced a thermal injury on the back of the thigh.It is unknown how the area was treated.The pads were put on for a short period of time before therapy was stopped, but the pads were left on.Therapy resumed and the skin injury was observed during the 6:00 am skin assessment on the following day.The patient cardiac arrested three times with a hypoxic injury and respiratory failure requiring intubation.The patient also had three vessel disease and went to the cath lab for stent placements.It is unknown if therapy was stopped for the procedure or if the patient was receiving therapy during that time.The patient also has a history of parkinson¿s disease with a brain implant.Per additional information received from the complaint via email on (b)(4) 2018: the wound care documentation from (b)(6) 2018 stated that the area on the posterior , distal right leg measured 5 x 3 x 0.1 cm.The area on the posterior left leg was 8.4 x.3.2 x.0.1-0.2 cm.The treatment for both areas was ag mesh to the wound beds which was changed every 3 days.Abdominal pads were placed for outer dressing and changed daily.There were 3 small abrasions on the right anterior knee which were cleansed with saline and covered with xeroform.The arctic sun treatment was discontinued.The pads had been on the patient for 2 days, however therapy was not continued for the full duration of those 2 days.The patient arrived hyperthermic with skin intact.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ARCTIC SUN TEMPERATURE MANAGEMENT SYSTEM, ARCTICGEL PADS
Type of Device
ARCTIC SUN GEL PADS
Manufacturer (Section D)
MEDIVANCE, INC. ¿ 1725056
321 s taylor ave
louisville CO 80027
Manufacturer (Section G)
MEDIVANCE, INC. ¿ 1725056
321 s taylor ave
louisville CO 80027
Manufacturer Contact
yonic anderson
8195 industrial blvd
covington, GA 30014
7707846100
MDR Report Key7850333
MDR Text Key119344976
Report Number1018233-2018-03985
Device Sequence Number1
Product Code DWJ
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K142702
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,other
Reporter Occupation Biomedical Engineer
Type of Report Initial,Followup
Report Date 12/04/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Expiration Date01/31/2019
Device Catalogue Number317-07
Device Lot NumberNGCNY602
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/12/2018
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 08/16/2018
Initial Date FDA Received09/06/2018
Supplement Dates Manufacturer Received11/28/2018
Supplement Dates FDA Received12/04/2018
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured01/29/2018
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Other;
Patient Age77 YR
Patient Weight65
-
-