• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: COOK INC THREE-WAY PLASTIC STOPCOCK; KGZ ACCESSORIES, CATHETER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

COOK INC THREE-WAY PLASTIC STOPCOCK; KGZ ACCESSORIES, CATHETER Back to Search Results
Catalog Number PTWS-2FLL-MLL-R
Device Problem Fluid/Blood Leak (1250)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 08/23/2018
Event Type  malfunction  
Manufacturer Narrative
Pma/510(k) number: exempt.This report includes information known at this time.A follow-up report will be submitted should additional relevant information become available.
 
Event Description
It was reported, during a tace (transcatheter arterial chemoembolization) procedure, leakage occurred from the stopcock.The physician had attempted to mix contrast medium and anti-cancer agent when the leakage was observed.Another manufacturer's device was used instead and the procedure was completed successfully.No patient adverse effects were reported.
 
Event Description
No additional information regarding the patient and/or event has been received since the previous medwatch report was sent.
 
Manufacturer Narrative
Blank fields on this form indicate the information is unknown, unavailable, or unchanged.Investigation ¿ evaluation.A review of the complaint history, device history record, documentation, drawing, manufactures instructions, quality control, and a functional test & visual inspection of the returned device were conducted during the investigation.The visual inspection of the returned device confirmed that there was a crack on the body of the device.During the functional test, the device was noted to have leaked through the crack when the stem was in the left position.No leaks were noted from the fitting when tested.However, the thru-hole was verified to be open when using a 0.65 pin gauge.Additionally, a document based investigation evaluation was performed.There is no evidence to suggest the product was not made to specifications.A review of the device history record showed no nonconforming events which could contribute to this failure mode.It should be noted there were no other reported complaints for this lot number.Furthermore, a review of the manufactures instructions and documentation revealed relevant information surrounding the mold used for this device.The material used for this device has the potential to absorb moisture, resulting in an increase in diameter, thus raising the potential for cracking the stopcock body.Based on the information provided, the examination of the returned product, and the results of our investigation, a definitive root cause can be traced to device designed.Measures are being conducted to address this failure mode.We will continue our monitoring of similar complaints and have notified the appropriate personnel of this event.Per the risk assessment no further action is required.This report is required by the fda under 21 cfr part 803.This report is based on unconfirmed information submitted by others.Neither the submission of this report nor any statement made in it is intended to be an admission that any cook device is defective or malfunctioned; that a death or serious injury occurred; or that any cook device caused or contributed to; or is likely to cause or contribute to a death or serious injury if a malfunction occurred.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
THREE-WAY PLASTIC STOPCOCK
Type of Device
KGZ ACCESSORIES, CATHETER
Manufacturer (Section D)
COOK INC
750 daniels way
bloomington IN 47404
MDR Report Key7870034
MDR Text Key120103454
Report Number1820334-2018-02666
Device Sequence Number1
Product Code KGZ
UDI-Device Identifier00827002002197
UDI-Public(01)00827002002197(17)181001(10)4577115
Combination Product (y/n)N
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,other,user facility
Type of Report Initial,Followup
Report Date 11/27/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date10/01/2018
Device Catalogue NumberPTWS-2FLL-MLL-R
Device Lot Number4577115
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/04/2018
Initial Date Manufacturer Received 08/24/2018
Initial Date FDA Received09/12/2018
Supplement Dates Manufacturer Received11/20/2018
Supplement Dates FDA Received11/27/2018
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-