MAUDE Adverse Event Report: ADVANCED STERILIZATION PRODUCTS CYCLESURE® 24 BIO INDICATOR; INDICATOR, BIOLOGICAL (FRC)

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ADVANCED STERILIZATION PRODUCTS CYCLESURE® 24 BIO INDICATOR; INDICATOR, BIOLOGICAL (FRC) Back to Search Results
Catalog Number 14324
Device Problem Appropriate Term/Code Not Available (3191)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 08/22/2018
Event Type  malfunction  
Manufacturer Narrative
(b)(4).
 
Event Description
A customer reported a positive result with a cyclesure® 24 biological indicator (bi) after a completed sterrad® 100s cycle.The bi was incubated for 24 hours.The chemical indicator (ci) changed color correctly.The previous and subsequent bi results were both negative.The affected load was released and used on a patient(s).It is unclear at this time if there is any report of infection, injury or harm to patient(s) associated with this issue.Asp will continue to follow-up for additional information.Although there is no report of patient injury or harm and no prior incidents have resulted in serious injury, advanced sterilization products (asp) has determined in this situation sterility cannot be assured.Therefore, as a matter of policy asp had decided to report all incidents of positive cyclesure® 24 biological indicators when the load has not been reprocessed prior to release for use.
 
Manufacturer Narrative
Upon further follow-up with the customer, the load was used on four patients.However, it was confirmed there is no report of infection, injury or harm to patient(s) associated with the issue.(b)(4).
 
Manufacturer Narrative
Correction from follow-up report on 9/13/2018.It was incorrectly stated.Upon further follow-up with the customer, the load was used on four patients.However, it was confirmed there is no report of infection, injury or harm to patient(s) associated with the issue.It was later confirmed that four instruments were used on four patients.The four instruments were from two different bis, same lot, different loads.It is unknown which instruments were from which load.A 2nd complaint was opened for the 2nd suspect bi and is reported under asp complaint ref #: (b)(4) and manufacturer report number: 2084725-2018-00712.Device evaluated by mfr: asp investigation summary: the investigation included a review of the device history record (dhr), trending of lot number, system risk analysis (sra), visual analysis and retains analysis.¿ the dhr was reviewed and the involved lot met manufacturer specifications at the time of release.No anomalies were observed that would contribute to the customer's experienced issue.¿ trending analysis by lot number was reviewed from 05/29/2018 to 08/22/2018 and trending was not exceeded.¿ the sra indicates the risk associated with exposure to biohazardous, pathogenic or infectious material is "low." ¿ the single cyclesure® 24 bi was not returned for visual inspection.¿ thirty-two retains bis were subject to functional evaluation.All thirty-two bis met specification.It is unlikely the suspected positive bi was caused by a manufacturing issue as the retains met functional specification, dhr review found no anomalies that would contribute to a positive bi result and lot history review found trending was not exceeded in this lot.An issue with sterrad® performance is also unlikely as the cycle passed and the chemical indicator disc changed correctly.The cyclesure® retains met functional specification.As a result, there is not an issue with product performance when used per the instructions for use (ifu).The issue will continue to be tracked and trended.Asp complaint ref #: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CYCLESURE® 24 BIO INDICATOR
Type of Device
INDICATOR, BIOLOGICAL (FRC)
Manufacturer (Section D)
ADVANCED STERILIZATION PRODUCTS
33 technology drive
irvine CA 92618
MDR Report Key7875045
MDR Text Key120242270
Report Number2084725-2018-00713
Device Sequence Number1
Product Code FRC
UDI-Device Identifier10705037016211
UDI-Public10705037016211
Combination Product (y/n)N
PMA/PMN Number
K994055
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Type of Report Initial,Followup,Followup
Report Date 08/22/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date04/30/2019
Device Catalogue Number14324
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 08/22/2018
Initial Date FDA Received09/13/2018
Supplement Dates Manufacturer Received09/13/2018
08/22/2018
Supplement Dates FDA Received10/10/2018
02/15/2019
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Treatment
STERRAD 100S STERILIZER, SERIAL #: (B)(4)
-
-