MAUDE Adverse Event Report: ZIMMER BIOMET, INC. UNKNOWN IMPACTOR HEAD; INSTRUMENT, SURGICAL

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ZIMMER BIOMET, INC. UNKNOWN IMPACTOR HEAD; INSTRUMENT, SURGICAL Back to Search Results
Model Number N/A
Device Problem Fracture (1260)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 09/17/2018
Event Type  malfunction  
Manufacturer Narrative
(b)(4).Medical devices: targeting guide catalog#: 00249000300 lot#: 62186171.It is unknown if the product will be returned to zimmer biomet for investigation.Once the investigation has been completed, a follow-up mdr will be submitted.
 
Event Description
It is reported that during a procedure while the surgeon attempted to insert the nail the threads of the impaction head fractured in the guide.No adverse events were a result of this malfunction.
 
Event Description
No further event information available at the time of this report.
 
Manufacturer Narrative
(b)(4).Complaint sample was evaluated and the reported event was confirmed.Visual inspection indicated the threads of the impactor head have fractured off and are retained in the jig handle.Device history record (dhr) review was unable to be performed as the lot number of the device involved in the event is unknown.Root cause was unable to be determined.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UNKNOWN IMPACTOR HEAD
Type of Device
INSTRUMENT, SURGICAL
Manufacturer (Section D)
ZIMMER BIOMET, INC.
56 e. bell drive
warsaw IN 46582
MDR Report Key7965710
MDR Text Key123944443
Report Number0001822565-2018-05722
Device Sequence Number1
Product Code HWR
Combination Product (y/n)N
PMA/PMN Number
PNI
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,distri
Type of Report Initial,Followup
Report Date 03/13/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberN/A
Was Device Available for Evaluation? No
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 09/18/2018
Initial Date FDA Received10/15/2018
Supplement Dates Manufacturer Received03/11/2019
Supplement Dates FDA Received03/13/2019
Is This a Reprocessed and Reused Single-Use Device? No
Removal/Correction NumberN/A
Patient Sequence Number1
-
-