• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ABBOTT MANUFACTURING INC CLINICAL CHEMISTRY CALCIUM

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ABBOTT MANUFACTURING INC CLINICAL CHEMISTRY CALCIUM Back to Search Results
Catalog Number 03L79-21
Device Problem High Test Results (2457)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 09/25/2018
Event Type  malfunction  
Manufacturer Narrative
An evaluation is in process.A follow-up report will be submitted when the evaluation is complete.
 
Event Description
The customer reported multiple false elevated architect calcium results on the architect c16000 analyzer.Sample id 9175964jp generated an initial result of 5.13 mmol/l and retest of 2.20 mmol/l.No adverse impact to patient management was reported.
 
Manufacturer Narrative
Review of complaint activity for lot 98314un17 did not identify an increase in complaint activity.Tracking and trending report review for the architect calcium assay did not identify any adverse or non-statistical trends that require further investigation.Manufacturing documentation for the assay did not identify any issues associated with the complaint issue.Additionally, labeling was reviewed and sufficiently addresses the customer's issue.No systemic issue or deficiency of the architect calcium assay was identified.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CLINICAL CHEMISTRY CALCIUM
Type of Device
CALCIUM
Manufacturer (Section D)
ABBOTT MANUFACTURING INC
1921 hurd drive
irving TX 75038
MDR Report Key7975515
MDR Text Key126096589
Report Number1628664-2018-01946
Device Sequence Number1
Product Code CJY
UDI-Device Identifier00380740005931
UDI-Public00380740005931
Combination Product (y/n)N
PMA/PMN Number
K981578
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional
Type of Report Initial,Followup
Report Date 01/29/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date02/27/2019
Device Catalogue Number03L79-21
Device Lot Number98314UN17
Was Device Available for Evaluation? Yes
Initial Date Manufacturer Received 10/03/2018
Initial Date FDA Received10/17/2018
Supplement Dates Manufacturer Received01/25/2019
Supplement Dates FDA Received01/29/2019
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Treatment
ARCHITECT C16000 ANALYZER; ARCHITECT C16000 ANALYZER; LIST 03L77-01, SERIAL (B)(4); LIST 03L77-01, SERIAL (B)(4)
-
-