Catalog Number 221750041
Device Problems Connection Problem (2900); Material Deformation (2976)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 11/23/2018
Event Type  malfunction  
Manufacturer Narrative
Product complaint # (b)(4).If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event Description
Thr: while impacting the shell into the acetabulum, the thread that was screwed into the definitive shell sheared off.Another handle was used from another set and another shell was opened as the first one was damaged getting it out of the patient.All pieces of the handle are accounted for.No harm came to the patient.It caused a delay of approx 5 mins.Pinnacle shell insertion handle.
 
Manufacturer Narrative
Product complaint # (b)(4).
 
Manufacturer Narrative
Product complaint # (b)(4).If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Manufacturer Narrative
Product complaint # : (b)(4).Examination of the returned instrument confirmed the complaint.Depuy considers the investigation closed at this time.Should additional information be received, the information will be reviewed and the investigation will be re-opened as necessary.If information is obtained that was not available for the initial medwatch , a follow-up medwatch, a follow-up medwatch will be filed as appropriate.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PINN STRAIGHT CUP IMPACTOR
Type of Device
HIP INSTRUMENTS : IMPACTORS
Manufacturer (Section D)
DEPUY ORTHOPAEDICS, INC. 1818910
700 orthopaedic dr.
warsaw IN 46582 0988
Manufacturer (Section G)
DEPUY ORTHOPAEDICS, INC. 1818910
700 orthopaedic dr.
warsaw IN 46582 0988
Manufacturer Contact
kara ditty-bovard
1210 ward avenue
west chester, PA 19380
6103142063
MDR Report Key8181148
MDR Text Key130902952
Report Number1818910-2018-78738
Device Sequence Number1
Product Code MRA
UDI-Device Identifier10603295098980
UDI-Public10603295098980
Combination Product (y/n)N
Reporter Country CodeAS
PMA/PMN Number
P070026
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation Physician
Type of Report Initial,Followup,Followup,Followup
Report Date 11/23/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number221750041
Device Lot NumberNT1209
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer12/19/2018
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 11/23/2018
Initial Date FDA Received12/19/2018
Supplement Dates Manufacturer Received11/23/2018
12/19/2018
01/15/2019
Supplement Dates FDA Received12/19/2018
01/11/2019
01/21/2019
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured12/15/2009
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
Patient Age81 YR
-
-