• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: TERUMO CARDIOVASCULAR SYSTEMS CORPORATION LARGE (6) ROLLER PUMP FOR TERUMO ADVANCED PERFUSION SYSTEM 1; PUMP, BLOOD, CARDIOPULMONARY BYPASS, ROLLER TYPE - 6 INCH ROLLER PUMP

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

TERUMO CARDIOVASCULAR SYSTEMS CORPORATION LARGE (6) ROLLER PUMP FOR TERUMO ADVANCED PERFUSION SYSTEM 1; PUMP, BLOOD, CARDIOPULMONARY BYPASS, ROLLER TYPE - 6 INCH ROLLER PUMP Back to Search Results
Model Number 816571
Device Problem Pumping Stopped (1503)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 12/07/2018
Event Type  malfunction  
Event Description
It was reported that during use of the device for a cardiopulmonary bypass (cpb) procedure, the arterial pump stopped for 11 seconds.The pump was restarted and worked correctly.The surgical procedure was completed successfully.There was no delay, no blood loss, nor adverse consequences to the patient.
 
Manufacturer Narrative
During laboratory analysis, the product surveillance technician (pst) was not able to duplicate the issue.The pst observed the pump to function as intended; no pump stops during testing per known user technique.
 
Manufacturer Narrative
The reported complaint was confirmed.The service repair technician (srt) was not able to duplicate the reported complaint.He replaced the pod assembly as a precaution.The unit operated to the manufacturer's specifications.If additional information becomes available on this complaint that would alter the facts and/or conclusion, a supplemental report will be filed accordingly.
 
Manufacturer Narrative
Per data log analysis, on (b)(6) 2018 the arterial large roller pump speed was set to 4.247 liters per minute (l/min) at 10:04:37am.At 10:04:45 am, the stop button was pressed on the central control monitor (ccm) arterial pump icon.The pump was started again at 10:04:56 am from the local pump control (not the ccm).Most likely the stop button was accidently pressed on the ccm.
 
Event Description
Per clinical review: on (b)(6) 2018, the roller pump used in the arterial position had no issue prior to initiation of cardiopulmonary bypass (cpb) procedure.The team used a 1/2 arterial tubing as the boot in their raceway.During the procedure, the roller pump stopped forward flow.According to the information available, there was no visual or audible alarms that indicated a stoppage of the forward flow of the roller pump.The perfusion team was able to engage the start/stop button and come up to an appropriate forward flow for the remainder of the procedure.The stoppage of the pump was for a total of 11 seconds.There was no harm associated with the event.This incident did not delay the surgical procedure, and there was no blood loss due to the occurrence.The team exchanged the heart lung machine (hlm) after the case to investigate the incident.It was stated that the connections from the pump to the network interface card (nic) board were tight, but that the last preventative maintenance (pm) on this system was february 1, 2018.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
LARGE (6) ROLLER PUMP FOR TERUMO ADVANCED PERFUSION SYSTEM 1
Type of Device
PUMP, BLOOD, CARDIOPULMONARY BYPASS, ROLLER TYPE - 6 INCH ROLLER PUMP
Manufacturer (Section D)
TERUMO CARDIOVASCULAR SYSTEMS CORPORATION
6200 jackson road
ann arbor MI 48103
MDR Report Key8184256
MDR Text Key131006626
Report Number1828100-2018-00654
Device Sequence Number1
Product Code DWB
Combination Product (y/n)N
PMA/PMN Number
K131618
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional,o
Type of Report Initial,Followup,Followup,Followup
Report Date 08/09/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number816571
Device Catalogue Number816571
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer05/01/2019
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 12/12/2018
Initial Date FDA Received12/20/2018
Supplement Dates Manufacturer Received01/04/2019
05/01/2019
07/30/2019
Supplement Dates FDA Received01/23/2019
05/22/2019
08/09/2019
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-