Catalog Number 210133
Device Problem Physical Resistance/Sticking (4012)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 08/11/2016
Event Type  malfunction  
Manufacturer Narrative
If additional information should become available, a supplemental medwatch will be submitted accordingly.(b)(4).The exp date is currently unavailable.The complaint device is not being returned, therefore unavailable for a physical evaluation.Historically, this type of failure has been attributed to user technique issue.The location of the trocar interlocking pins is superior to the mating portion of the sleeve.If the pins are not seated within these groves then the trocar is spinning within the guide sleeve causing enough heat and friction to cause the "welding" of the two parts.Further, a review into the depuy synthes mitek complaints system revealed no other complaints of any kind for this lot of devices that were released to distribution.We cannot discern a root cause for the reported failure mode.At this point in time, no corrective action is required and no further action is warranted.This file will remain receptive to any potential forthcoming information received that is pertinent and germane to this issue.However, depuy synthes mitek will continue to track any related complaints within this device family as a means of monitoring the extent with which this complaint is observed in the field.This report is being filed from the (b)(4) as required under mitek's corrective and preventative actions (capa) to file usa fda mdr missed malfunctions.
 
Event Description
This is report 2 of 2 for the same event.It was reported by the affiliate in (b)(6) that during a left anterior cruciate ligament acl reconstruction soft tissue surgical procedure, during use of the 'rigidfix soft tissue guide' instrument to place the single use trocars from a 'rigidfix femoral st cross pin kit' via drill power, it was observed that the guide and trocar have cold welded together.The surgeon was unable to advance the trocar into the appropriate position.There was no harm caused to the patient.There was visual damage noted to the instrument and trocar.The guide and trocar were removed and a second 'rigidfix soft tissue guide' instrument and 'rigidfix femoral st cross pin kit' were opened and used successfully to complete the case.There was a delay in the surgical procedure of 10 minutes.There was patient involvement reported.There were no injuries, medical intervention or prolonged hospitalization.All available information has been disclosed.If additional information should become available, a supplemental medwatch report will be submitted accordingly.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
RIGIDFIX FEM 3.3MM S/T XPIN
Type of Device
SOFT-TISSUE ANCHOR, BIOABSORBABLE
Manufacturer (Section D)
DEPUY MITEK LLC US
325 paramount drive
raynham MA 02767
Manufacturer (Section G)
DEPUY MITEK LLC US
325 paramount drive
raynham MA 02767
Manufacturer Contact
kara ditty-bovard
325 paramount drive
raynham, MA 02767
6013142063
MDR Report Key8282089
MDR Text Key135009628
Report Number1221934-2018-52226
Device Sequence Number1
Product Code HTY
UDI-Device Identifier10886705000890
UDI-Public10886705000890
Combination Product (y/n)N
Reporter Country CodeAS
PMA/PMN Number
K974341
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation Other
Type of Report Initial
Report Date 08/11/2016
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number210133
Device Lot Number3887280
Initial Date Manufacturer Received 08/11/2016
Initial Date FDA Received01/28/2019
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-