Model Number N/A
Device Problem Manufacturing, Packaging or Shipping Problem (2975)
Patient Problem No Patient Involvement (2645)
Event Date 02/01/2019
Event Type  malfunction  
Manufacturer Narrative
(b)(4).Foreign source- (b)(6).Customer has indicated that the product is in process of being returned to zimmer biomet for investigation.Once the investigation has been completed, a follow-up mdr will be submitted.
 
Event Description
It was reported that during receiving inspection, debris was found in the sterile packaging.There was no patient involvement.
 
Event Description
No additional information was reported.
 
Manufacturer Narrative
This follow-up report is being submitted to relay additional information.The reported event was confirmed by visual evaluation; debris was found in the sterile packaging.Ftir analysis conducted on the foreign material in the package was consistent with a spectrum of nylon type-6.Device history record was reviewed and no discrepancies relevant to the reported event were found.The root cause of the reported event can be attributed to the operator not following instructions during manufacturing.If any further information is found which would change or alter any conclusions or information, a supplemental report will be filed accordingly.Zimmer biomet will continue to monitor for trends.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FIB ANATOMIC LOCK LEFT 4H STE
Type of Device
PLATE, FIXATION
Manufacturer (Section D)
ZIMMER BIOMET, INC.
56 e. bell drive
warsaw IN 46582
MDR Report Key8370145
MDR Text Key137260912
Report Number0001825034-2019-00788
Device Sequence Number1
Product Code HRS
Combination Product (y/n)N
PMA/PMN Number
K111663
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type distributor,foreign
Type of Report Initial,Followup
Report Date 09/27/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberN/A
Device Catalogue Number856206004
Device Lot Number147380
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer03/06/2019
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 02/01/2019
Initial Date FDA Received02/26/2019
Supplement Dates Manufacturer Received09/23/2019
Supplement Dates FDA Received09/30/2019
Is This a Reprocessed and Reused Single-Use Device? No
Removal/Correction NumberN/A
Patient Sequence Number1
-
-