Catalog Number UNK HIP INSTRUMENTS
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problem Not Applicable (3189)
Event Date 02/14/2019
Event Type  Injury  
Manufacturer Narrative
If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.Device was used for treatment, not diagnosis.This report is for an unknown device/unknown lot.Part and lot number are unknown; udi number is unknown.(b)(4).
 
Event Description
Patient underwent an endoprosthesis procedure with a corail cemented stem due to a fractured hip.During the procedure, while the surgeon was broaching using the corail broach, the femur broke.It was a major fracture and surgeon had put a cable to fix the fracture and used a long revision stem.A total hip procedure was done instead of just an endoprosthesis procedure.The procedure was successfully completed with a surgical delay of one hour.The patient status is unknown.
 
Manufacturer Narrative
Product complaint # (b)(4).Investigation summary
=
> the device associated with this report was not returned.Depuy considers the investigation closed at this time.Should additional information be received, the information will be reviewed and the investigation will be re-opened as necessary.If information is obtained that was not available for the initial medwatch, a follow-up medwatch, a follow-up medwatch will be filed as appropriate.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UNKNOWN HIP INSTRUMENTS
Type of Device
HIP INSTRUMENTS
Manufacturer (Section D)
DEPUY ORTHOPAEDICS, INC. 1818910
700 orthopaedic drive
warsaw IN 46582 0988
Manufacturer (Section G)
DEPUY ORTHOPAEDICS, INC. 1818910
700 orthopaedic drive
warsaw IN 46582 0988
Manufacturer Contact
kara ditty-bovard
1210 ward avenue
west chester, IN 19380-0988
6103142063
MDR Report Key8400402
MDR Text Key138129704
Report Number1818910-2019-86744
Device Sequence Number1
Product Code JDG
Combination Product (y/n)N
Reporter Country CodeCA
PMA/PMN Number
UNK
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 02/15/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Catalogue NumberUNK HIP INSTRUMENTS
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Initial Date Manufacturer Received 02/15/2019
Initial Date FDA Received03/07/2019
Supplement Dates Manufacturer Received05/14/2019
Supplement Dates FDA Received05/14/2019
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
-
-