MAUDE Adverse Event Report: C.R. BARD, INC. (COVINGTON) -1018233 AVAULTA SOLO¿ SYNTHETIC SUPPORT SYSTEM - ANTERIOR, STERILE; AVAULTA SOLO ANTERIOR

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

C.R. BARD, INC. (COVINGTON) -1018233 AVAULTA SOLO¿ SYNTHETIC SUPPORT SYSTEM - ANTERIOR, STERILE; AVAULTA SOLO ANTERIOR Back to Search Results
Catalog Number 486100
Device Problems Material Erosion (1214); Patient-Device Incompatibility (2682); Material Protrusion/Extrusion (2979)
Patient Problems Erosion (1750); Hemorrhage/Bleeding (1888); Incontinence (1928); Abnormal Vaginal Discharge (2123)
Event Date 01/01/2015
Event Type  Injury  
Manufacturer Narrative
The investigation is still in progress.Once the investigation is complete a supplemental report will be filed.The device was not returned.
 
Event Description
It was reported that a patient had several mesh implants which resulted in mesh extrusion requiring surgery to remove.The patient experienced bleeding (vaginal), discharge (vaginal), urinary leaking, and additional surgery.The patient also had mesh erode into her rectum.She is on estrogen to keep the vaginal walls thick.
 
Event Description
It was reported that a patient had several mesh implants which resulted in mesh extrusion requiring surgery to remove.The patient experienced bleeding (vaginal), discharge (vaginal), urinary leaking, and additional surgery.The patient also had mesh erode into her rectum.She is on estrogen to keep the vaginal walls thick.
 
Manufacturer Narrative
The device was not returned for evaluation.The device history record was reviewed and found nothing that could have caused or contributed to the reported event.The instructions for use were found adequate and state the following: ¿¿ note: the avaulta solo¿ support system does not require a particular orientation with respect to mucosal or visceral sidedness.¿ proximal end with apical flap positioned at vaginal apex ¿ proximal arms (long arms with pointed ends) passed through inferior medial aspect of obturator membrane ¿ distal end positioned at bladder neck ¿ distal arms (short arms with rounded ends) passed through superior medial aspect of obturator membrane 1.Place the patient in stirrups in the lithotomy position and prepare for surgery using standard operative procedures.2.Make a midline incision in the anterior vaginal wall starting 1 cm below the urethral meatus and extending to the vaginal cuff.Dissect the vaginal mucosa away from the bladder laterally to the obturator internus at the level of the bladder neck and proximally to the ischial spine on both sides.3.Identify the obturator fossa by grasping the adductor longus at its insertion to the pubic tubercle.Using the thumb to palpate under the adductor longus insertion, the superior medial aspect of the obturator fossa is identified.Palpate and draw the medial border of the obturator fossa to its inferior medial border.Make a vertical 1.5 cm incision approximately 1 cm below the superior medial border of the obturator fossa and lateral to the bladder neck for the distal arm of the mesh.Make a second vertical 1.5 cm incision at the inferior medial border of the obturator fossa and approximately lateral to the vaginal cuff.Repeat on the contralateral side.4.Locate the introducer needle and ensure that the snare is fully retracted into the needle tip prior to inserting the needle.Insert the tip of the introducer needle into the inferior medial groin incision to puncture through the obturator membrane.Orient the introducer in a horizontal plane, and direct the needle tip towards the ischial spine or top of the vaginal cuff.Identify the tip of the introducer before puncturing through the obturator internus muscle.With a gentle rotation of the introducer push through the obturator muscle and use the vaginal finger to guide the needle tip through the fascial wall to exit proximally at the vaginal apex, exposing at least 1-2 cm of the needle tip.Insert a right-angle retractor into the vagina along the anterior wall and extend the introducer snare using the thumb slider on the introducer handle.The introducer tip should be stabilized with two fingers during initial deployment of the snare.If necessary, guide the end of the snare to the introitus with a finger.Extend the thumb slider until the snare loop has fully exteriorized itself.5.Pass the proximal arm (pointed end) of the mesh up to the fold (about 5 cm) through the eyelet in the snare.Retract the snare using the thumb slider until it reaches the stop position.Take care to prevent the surrounding tissue from getting caught in the snare during retraction.Retract the introducer needle to draw the mesh arm out through the inferior groin incision.Ensure the mesh arm is not twisted during or after placement.Repeat steps 4 and 5 on the contralateral side.Note: if substantial resistance is felt during retraction of the introducer needle, ensure that no tissue has been caught in the needle during the snare retraction.Should this occur, re-extend the snare using the thumb slider mechanism, remove the trapped tissue, and re-retract the snare." patient code: 2564.H11:section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text : the device was not returned.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AVAULTA SOLO¿ SYNTHETIC SUPPORT SYSTEM - ANTERIOR, STERILE
Type of Device
AVAULTA SOLO ANTERIOR
Manufacturer (Section D)
C.R. BARD, INC. (COVINGTON) -1018233
8195 industrial blvd
covington GA 30014
MDR Report Key8579428
MDR Text Key144095821
Report Number1018233-2019-02325
Device Sequence Number1
Product Code OTP
UDI-Device Identifier00801741168024
UDI-Public(01)00801741168024
Combination Product (y/n)N
PMA/PMN Number
K083839
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type consumer,other
Type of Report Initial,Followup
Report Date 07/11/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date09/01/2010
Device Catalogue Number486100
Device Lot NumberHUSI1687
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 04/11/2019
Initial Date FDA Received05/03/2019
Supplement Dates Manufacturer Received06/23/2019
Supplement Dates FDA Received07/11/2019
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
-
-