Model Number 505DA18
Device Problem Insufficient Information (3190)
Patient Problem Occlusion (1984)
Event Date 04/15/2019
Event Type  Injury  
Manufacturer Narrative
Product analysis: no product was returned.Conclusion: without the return of the product, no definitive conclusion can be made regarding the clinical observation.If information is provided in the future, a supplemental report will be issued.
 
Event Description
Medtronic received information that immediately following implant of this 18 mm aortic mechanical valve, the valve was explanted and replaced with a 16 mm mechanical valve (manufacturer unknown).It was reported that post implant there was a coronary occlusion identified when retrograde cardioplegia was infused to check the status of the coronary circulation.The surgeon reported that the cause of the occlusion was the influence of a non-medtronic mitral mechanical valve and small sinus of valsalva (sov).The surgeon also reported that the patient had a rigid non-coronary cusp (ncc) which prevented extension of the aortic annulus.No additional adverse patient effects were reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AORTIC AP
Type of Device
HEART-VALVE, MECHANICAL
Manufacturer (Section D)
MEDTRONIC HEART VALVE DIVISION
3800 annapolis lane
minneapolis MN 55447
Manufacturer (Section G)
MEDTRONIC HEART VALVE DIVISION
3800 annapolis lane
minneapolis MN 55447
Manufacturer Contact
paula bixby
8200 coral sea street ne
mounds view, MN 55112
7635055378
MDR Report Key8596098
MDR Text Key144584779
Report Number3008592544-2019-00019
Device Sequence Number1
Product Code LWQ
Combination Product (y/n)N
Reporter Country CodeJA
PMA/PMN Number
P990046
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type health professional
Reporter Occupation Other
Type of Report Initial
Report Date 05/09/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Expiration Date05/30/2024
Device Model Number505DA18
Device Catalogue Number505DA18
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 04/19/2019
Initial Date FDA Received05/09/2019
Date Device Manufactured05/30/2017
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
Patient Age78 YR
-
-